background image

 

 

Ingenico – 28-32 Boulevard de Grenelle - 75015 PARIS 
Tél. 33(0)1 58 01 80 00 - Fax 33 (0)1 58 01 91 35 

 

 

 

 

 

 
 
 
 
 
Contactless payment  
iUC150 & iUC180

 

 
 
 
 
 

In

t

é

g

r

a

t

io

n

 G

u

id

e

 

 

Содержание iUC150

Страница 1: ...Ingenico 28 32 Boulevard de Grenelle 75015 PARIS T l 33 0 1 58 01 80 00 Fax 33 0 1 58 01 91 35 Contactless payment iUC150 iUC180 I n t g r a t i o n G u i d e...

Страница 2: ...such as iUC150 and iUC180 or others It offers all information needed for a successful integration of iUC150 and iUC180 products into unattended kiosk machines For any sales information please refer to...

Страница 3: ...ad 23 1 3 1 9 Cable Protection 24 1 3 1 10 Antenna Installation 25 1 3 1 11 Grounding connections 26 1 3 1 12 Appearance personalisation 27 1 3 2 iUC150 29 1 3 2 1 Technical Hardware characteristics 2...

Страница 4: ...ical requirements 56 5 2 General installation recommendations 56 5 3 Kiosk suggested layouts for iUC150 iUR250 IUP250 57 6 ASSEMBLY PROCEDURE FOR IUC180 AND IUC150 57 6 1 Kiosk minimum volume for iUC1...

Страница 5: ...10 STANDARDS 67 10 1 iUC 150 Electrical consumptions 67 10 2 iUC 180 Electrical consumptions 67 10 3 Temperature and humidity 67 10 4 Environmental specification continued 67 10 5 EC standard complian...

Страница 6: ...S General Packet Radio Service GSM Global System for Mobile communications LCD Liquid Crystal Display LLT Local Loading Tool MDB Multi Drop Bus RAM Random Access Memory RS232 Recommended Standard 232...

Страница 7: ...VA standard Usage can be indoor or outdoor resisting to harsh environment Remarks For iUC180 additional peripherals can be added to build a complete solution such as printer or bar code reader Ingenic...

Страница 8: ...am of iUC180 iUC150 connectivity and communications iUC150 display Contactless cards Power supply Main Power supply Ethernet 4 USB host Serial port com0 GSM GPRS Serial port com0 USB device MDB master...

Страница 9: ...ation SDK Support Hot line support Technical assistance After Sales Service Fixed cost repair of iUN products Downloading server centre User licence Installation and commissioning User training Hot li...

Страница 10: ...Int gration Guide_iUC150 iUC180 10 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 1 3 DESCRIPTION OF MODULES 1 3 1 iUC180 Front view Rear view...

Страница 11: ...imum backward leaning No constraints Power Supply 12 30 V Max 3A Platform Telium2 Memory 16 Mb SDRAM and 128 Mb Flash Functionality Contactless cards reading 128 x 64 graphic display RGB Backlight Buz...

Страница 12: ...ion Guide_iUC150 iUC180 12 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 1 3 1 2 iUC180 output connectors description COM 0 MDB Slave MDB Master SIM 2 SAMs SD COM2 Link Wake...

Страница 13: ...1 3 1 2 1 Ethernet The iUC180 contactless Reader unit can be connected to Ethernet The connector type is shielded RJ45 The Ethernet cable is standard and not provided The Ethernet cable must be shiel...

Страница 14: ...designed to save power thanks to a stand by mode If the stand by mode is used use Wake up mechanism with button connected on jack optional with Pin 2 of COM0 link COM2 link by pressing the green key...

Страница 15: ...less reader unit can be connected to serial port COM0 The connector type is RJ11 Pin N Function 1 GND 2 Wake up 3 RXD 4 TXD 5 CTS 6 RTS 1 3 1 2 6 COM2 link optional The iUC180 contactless reader unit...

Страница 16: ...te B F ELECTRONICS CO LTD ref MD 05 265C or equivalent must be added on the power cable 1 3 1 2 8 MDB master optional The iUC180 contactless reader unit can be connected by MDB master if option availa...

Страница 17: ...act commercial service to purchase it 1 3 1 2 10 Bluetooth optional When the iUC180 contactless reader is ordered with Bluetooth option it must be connected to an external Bluetooth antenna Ingenico c...

Страница 18: ...n provide an antenna or a standard one can be used This standard Antenna must have an impedance of 50 Ohm and a maximum gain of 3 5 dBi The SIM used for GSM functionality must be assigned to SIM slot...

Страница 19: ...3 1 3 SAM SD Installation 1 Disconnect the iUC180 contactless reader from the main power supply 2 Open the SAM door by removing the screw 3 Insert the SAM cards in SAM slot 1 and or slot 2 4 Insert S...

Страница 20: ...in excess the cards After insertion the cards position is 4 mm out of the products as shown on picture 1 3 1 4 Buzzer The buzzer is controlled by application The frequency depends of software 1 3 1 5...

Страница 21: ...1 000 01 1223 All rights reserved 1 3 1 6 Contactless LEDs Contactless Logo The iUC180 contains 4 green LEDs dedicated to Contactless application and one blue backlighted Contactless logo Green LEDs C...

Страница 22: ...and LED The iUC180 contactless reader has a maintenance button at the back To enter LLT mode press the button at power up or at restart until the red LED lights on To enter Maintenance mode press the...

Страница 23: ...de_iUC150 iUC180 23 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 1 3 1 8 Keypad Remarks The rear display and the keyboard can only be used in maintenance mode and are used...

Страница 24: ...served 1 3 1 9 Cable Protection A cable sealing sleeve is provided with iUC180 to protect the top of product against water runoff Connect the cables and snap in the part on the rear cover to cover the...

Страница 25: ...A tool is provided to help screwing the external antenna 1 Remove the antenna tool from the cable sleeve 2 Insert the SMA antenna cable through the slot of the antenna tool 3 Slide the antenna tool o...

Страница 26: ...Int gration Guide_iUC150 iUC180 26 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 1 3 1 11 Grounding connections The grounding connections must respect the following scheme...

Страница 27: ...o 900009816 R11 000 01 1223 All rights reserved 1 3 1 12 Appearance personalisation 1 Remove the 4 CHC M4 X 10 screws 2 Dismount the front cover 3 Put the film as shown in the pictures 4 Screw the fro...

Страница 28: ...C150 iUC180 28 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved Film Dimensions for iUC180 2D drawing at your disposal for serigraphic process Warning The film must not use met...

Страница 29: ...Ingenico 900009816 R11 000 01 1223 All rights reserved 1 3 2 iUC150 1 3 2 1 Technical Hardware characteristics iUC150 technical characteristics Mass 550 g Dimensions 250 x 120 x 53 mm 67 with cable pr...

Страница 30: ...Functional temperature 20 C 65 C Max relative humidity 85 at 55 C non condensing Fixing Tilt No constraints Power Supply USB 5V 500 mA Platform Telium2 Functionality Buzzer Link USB device RS232 conne...

Страница 31: ...USB 1 3 2 2 2 Wake up mechanism iUC150 is design to save power thanks to a stand by mode To wake up iUC150 use Wake up mechanism Pin 2 of COM0 link drive the wake up mechanism Wake up pin state Hz hi...

Страница 32: ...s reader unit can be connected to serial port COM0 The connector type is RJ11 Pin N Function 1 GND 2 Wake up 3 RXD 4 TXD 5 CTS 6 RTS PINPad iUP 250 Contactless Card Reader iUC 150 USB COM0 1 GND 2 Wak...

Страница 33: ...00 01 1223 All rights reserved 1 3 2 3 SAM Installation 1 Disconnect the iUC150 from the main power supply 2 Open the SAM door by removing the screw 3 Insert the SAM cards in SAM slot 1 and or slot 2...

Страница 34: ...All rights reserved For SAM SIM cards take care of cards orientation and do not push in excess the cards After insertion the cards position is 4 mm out of the products as shown on picture 1 3 2 4 Buz...

Страница 35: ...1 000 01 1223 All rights reserved 1 3 2 5 Contactless LEDs Contactless Logo The iUC150 contains 4 green LEDs dedicated to Contactless application and one blue backlighted Contactless logo Green LEDs C...

Страница 36: ...3 All rights reserved 1 3 2 6 Cable Protection A cable sealing sleeve is provided with iUC180 to protect the top of product against water runoff Connect the cables and snap in the part on the rear cov...

Страница 37: ...Int gration Guide_iUC150 iUC180 37 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 1 3 2 7 Grounding connections The grounding connections must respect the following scheme...

Страница 38: ...co 900009816 R11 000 01 1223 All rights reserved 1 3 2 8 Appearance personalisation 1 Remove the 4 CHC M4 X 10 screws 2 Dismount the front cover 3 Put the film as shown in the pictures 4 Screw the fro...

Страница 39: ...3 2 9 Contactless reader iUC150 and i9500 interconnectivity Connection between the iUC150 and i9500 is done through RS232 Plug the RS232 cable on iUC150 and i9500 with an Ingenico RS232 cable Use the...

Страница 40: ...e to install or integrate our products Furthermore they must follow a specific technical training conducted by Ingenico technical experts In addition installation must follow Ingenico recommendations...

Страница 41: ...hts reserved 2 1 3 iUC150 Power supply Ingenico power supply can be ordered under reference 192017549 only for 0 to 40 C use Input Main voltage supply ranging from 100V to 240V Maximum current of 3A W...

Страница 42: ...Int gration Guide_iUC150 iUC180 42 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 2 1 5 Adapter cable 2 1 6 LLT cable...

Страница 43: ...Int gration Guide_iUC150 iUC180 43 70 Copyright 2012 Ingenico 900009816 R11 000 01 1223 All rights reserved 2 1 7 Stand by management cable Definition of the jack connector...

Страница 44: ...th Telium2 technology is designed with a structure supporting several applications without any mutual interference The operating system is a multi task real time preemptive system The inputs and outpu...

Страница 45: ...Module Component UCMC for iUC180 Independent applications for iUC180 Telium manager System Applications Resident loading Bootstrap Power up Operating system Local loading Application manager Download...

Страница 46: ...herals It can also manage the transaction flow The applications are modeled around the demands made by the multi application manager Each request or input point represents a processing operation to be...

Страница 47: ...maintenance sub system ensures among other things the downloading of the application software The operating system ensures the start of the multi task core and then runs the applications by making a s...

Страница 48: ...equipped with its system and the application manager For iUC180 To operate the system unit has to be equipped with its system the application manager the UCMC and at least one application If no applic...

Страница 49: ...ged in Then launch the download by using the manager menu Diagnostics The diagnostics function is used for Local diagnostics The operator can request the incidents or alarms stored in the terminal The...

Страница 50: ...These features provide faster downloading time enhanced security an ease in upgrading and a larger number of software installed on the system unit Local Loading Tool LLT The LLT is used for local soft...

Страница 51: ...cs Softwares are loaded by FTP TCP IP and PPP for optimized loading Downloading performance in V32bis is around 1 4 kbps on the original files Once the connection is set up with the V32bis modem a 120...

Страница 52: ...he identity of the business is not requested The identity stored in the system unit is automatically transmitted to the server Using the application software on request by the center or merchant Examp...

Страница 53: ...a cross compiler are required These comprise A C compiler GNU an assembler and a link editor for ARM and Thumb A development environment A remote debugger Supply The SDK 30 development station compri...

Страница 54: ...rights reserved Technical support Duration 6 months after the training This includes the hot line and updates to the documentations and softwares during this period Software package A set of software...

Страница 55: ...NCTIONS The advanced functions are extremely various with new ones being requested frequently draw statistics and reports about terminal configurations optimise automatic call scheduling download bala...

Страница 56: ...metal parts near the antenna the performance may not be correct 5 2 GENERAL INSTALLATION RECOMMENDATIONS Installation requirements Ensure that you have enough free space for installation operational a...

Страница 57: ...y ingenico to optimise unattended modules integration See specific document iUP250 iUR250 integration guide 6 ASSEMBLY PROCEDURE FOR IUC180 AND IUC150 6 1 KIOSK MINIMUM VOLUME FOR IUC180 The iUC180 re...

Страница 58: ...co 900009816 R11 000 01 1223 All rights reserved 6 2 KIOSK MINIMUM VOLUME FOR IUC150 The iUC150 requires a minimum volume inside the kiosk It is detailed in the drawing below 3D design on demand The m...

Страница 59: ...the diagram below all dimensions are in millimeters The drawing below shows the footprint of iUC150 iUC180 products CAUTION It is important that the iUC150 iUC180 footprint surface on the kiosk must...

Страница 60: ...for integration into a kiosk Screw the 4 nuts M4 with a 1 0 N m torque It is recommended to use washers Picture showing a new installation of the iUC180 or iUC150 Installation of the iUC180 or iUC150...

Страница 61: ...TO THE KIOSK GROUND Picture showing the grounding of the iUC180 To insure good connexion of iUC180 or iUC150 to the kiosk ground it is recommended to install one copper braid connecting the 2 groundi...

Страница 62: ...g by USB key For more information concerning configuration contact Ingenico Technical Support 7 2 OPERATING LIFE Minimum operating life of 5 years 8 CLEANING INSTRUCTIONS The external front face of th...

Страница 63: ...in the Ingenico product s have to be removed and selectively treated Les composants et mat riaux suivants si pr sents dans le s produit s Ingenico doivent tre retir s et faire l objet d un traitement...

Страница 64: ...demment identifi s et n cessitant un traitement s lectif Step Etape Product disassembly process Processus de d montage du produit 1 Remove the 4 screws of front casing and of the rear cover Oter les 4...

Страница 65: ...ponents and materials Composants et mat riaux Quantity included in product s Quantit contenue dans le s produit s Capacitors containing Polychlorinated biphenyls PCB Condensateurs contenant du polychl...

Страница 66: ...of front casing and of the rear cover Oter les 4 vis du caport avant et du capot arri re 2 Remove the cover Oter le capot 3 Remove the 4 screws on the extension card Lift the card disconnect the FPC...

Страница 67: ...for host solicitation 12 VDC input Less than 120 mA Value measured for Power supply 5V at 25 C Maximum average external supply current 12 VDC input Less than 2500 mA Value measured for Power supply 5V...

Страница 68: ...quivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conform ment la r glementation d Industrie Canada le pr sent metteur radio peut fonctionner...

Страница 69: ...ible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of...

Страница 70: ...d batteries The associated symbol means that WEEE and waste batteries must not be thrown away but collected separately and recycled Ingenico ensures that efficient collection and recycling schemes are...

Отзывы: