15
At this point you must turn on your calibration gas. When the gas is on press
MODE otherwise once again you can exit the calibration by pressing MODE
EXIT.
This window will now display the current concentration values for the gases. By
watching this window you can see when the gas is stabilized within the analyzer.
The Go will flash to indicate that you must press MODE for the calibration to
begin. When you press the MODE the CAL enunciator will begin flashing and
the lower right window will go blank. This tells you calibration is in process.
When the calibration is complete you will see:
Once again the Go will flash indicating you must press MODE. You have now
completed the calibration process and the analyzer will do a purge and return to a
standby state.
F A C T O R Y C A L I B R A T I O N R E S E T :
At any time during the calibration when the analyzer is waiting for input from the operator, the MODE EXIT
button can be selected to abort the calibration. At this point the analyzer will display:
Use ▼ or ▲ to select between yes and no. If you select yes the analyzer will reset
to the calibration values used at the time it left the factory. If you select no the
analyzer will leave the calibration values as they were before the calibration was
started.
G P M M E A S U R E M O D E :
In the Measure Mode Options when GPM is selected the analyzer will compute grams per mile (or kilometer)
when the analyzer is put in Measure Mode (by pressing the MEASURE button). Once in measure mode the
analyzer will display:
The Measure light will start flashing. In the middle right window the starting
odometer reading should be entered (truncating off the mileage over 1000). This
can be in units of miles or kilometers depending if you want to measure Grams
per Mile or Grams per Kilometer. In the lower right window the engine
displacement should be entered. To set both values use ▲ and ▼ to change the
number that is currently flashing. To move to another digit or field use the ◄ or
► button. You can move to the next window by pressing the MODE button.
When both values have been entered press the MEASURE button to start the measurement. A counter will
appear in the lower right window showing the number of seconds the test has run. During this time the car
should be run through the test procedure for IM240, or any other test procedure defined by your area. The
analyzer does not make any assumptions about the test being run.
Turn Cal
Gas
On
Go
CAL
HC
0000 00.00
CO
CO2
00.00
00.00
O2
NOX
0000 Go
CAL
Turn off
cal gas
Go
CAL
RESE T TO
FACT ORY
YES
GPM TEST
ODOR 000.0
Litr 00.00
Содержание FGA
Страница 1: ...FGA4000XDS Four and Five Gas Analyzer ...
Страница 2: ...1 ...
Страница 4: ...3 ...
Страница 8: ...7 ...
Страница 18: ...17 ...
Страница 34: ...33 ...
Страница 40: ...39 ...
Страница 46: ...45 ...
Страница 48: ...47 ...
Страница 50: ...49 ...
Страница 52: ...51 ...
Страница 54: ...53 ...
Страница 56: ...55 ...
Страница 58: ......