33
CHAPTER 6 – Commissioning
SMT-BD2/m
1.
3
-
H
ALL
E
FFECT
S
ENSORS CONFIGURATION
If the motor is equipped with Hall Effect Sensors devices, select the following COM jumpers setting according to
the HES type (60° or 120°).
If the motor is not equipped with Hall Effect Sensors devices, the following COM jumpers setting must be
selected. In this case a motor phasing procedure must be executed at each amplifier power up.
1.
4
-
M
OTOR THERMAL SENSOR CONFIGURATION
Select the right MN or OP jumper setting according to the motor thermal sensor type (PTC or NTC).
1.4.1 - PTC thermal sensor
On motors equipped with a PTC thermal sensor (triggering on high impedance), the amplifier configuration is the
following: MN jumper closed and OP jumper open. The triggering threshold adjustment for the PTC thermal
sensor is made by means of the PSTH components, as described below : PSTH-D = 14,3 k
Ω
; PSTH-B = 28 k
Ω
;
PSTH-A = 3 x RPTC (120°C) in k
Ω
. RPTC (120°C) = ohmic value of the PTC thermal sensor resistor at 120°C;
the default adjustment is RPTC (120°C)
#
3 k
Ω
with PSTH-A = 10 k
Ω
.
1.4.2 - NTC thermal sensor
On motors equipped with a NTC thermal sensor (triggering on low impedance), the amplifier configuration is the
following: OP jumper closed and MN jumper open. The triggering threshold adjustment for the NTC thermal
sensor is made by means of the PSTH components, as described below: PSTH-D = 14,3 k
Ω
; PSTH-B = 28 k
Ω
;
PSTH-A = 3 x RNTC (120°C) in k
Ω
. RNTC (120°C) = ohmic value of the NTC thermal sensor resistor at 120°C;
the default adjustment is RNTC (120°C)
#
3 k
Ω
with PSTH-A = 10 k
Ω
.
1.5
-
C
URRENT LOOPS ADJUSTMENTS
1.5.1 - Current loops adjustments for the 400 VAC amplifier version
Select the right current loops jumpers setting (B1, B2 or B3 position) according to motor and amplifier
specifications.
For the 400VAC version of the BL MAVILOR motor series, the current loops adjustments are made according to
the following selection table.
AMPLIFIER
15 A
30 A
45 A
60 A
100 A
MOTOR
BL 113
B2
BL 114
B2
BL 115
B2
B1
BL 141
B1
B1
BL 142
B2
B1
BL 143
B1
B1
B1
BL 144
B1
B1
B1
BL 191
B3
B3
B2
BL 192
B3
B3
B2
60° HES type
COM
B5
B4
B3
120° HES type
COM
B5
B4
B3
COM
B5
B4
B3