63
SMT-BD2/m
CHAPTER 9 – Appendix
If the user sends the instruction:
NP
The amplifier will answer with:
NP:4
>
As there is no parameter in the instruction, the amplifier sends back the actual number of pole pairs.
6.2
-
INSTRUCTIONS
LIST
6.2.1 – Positioning instructions
Modify position of a sequence
Instruction UP
Parameters
1st parameter: sequence number.
2nd parameter: position value.
If there is no 2nd parameter, the amplifier will return the actual position value of the sequence
(1st
parameter).
Conditions
This instruction can be sent only if there is no sequence executed.
The sequence must exist.
Unit
The unit of the position value is defined by "position resolution" and "decimal number"
defined in the BD2m software. The value must be sent without the decimal point.
Example :
position resolution : 5000
decimal
number
:
3
unit : mm
If the user wants to set a value 100 mm to sequence 3, the instruction will be:
UP3,100000 (in decimal mode)
Modify speed of a sequence
Instruction US
Parameters
1st parameter: sequence number.
2nd parameter: speed.
If there is no 2nd parameter, the amplifier will return the actual speed of the sequence (1st
parameter).
Conditions
This instruction can be sent only if no sequence is executed.
The sequence must exist.
The minimum speed is 2 rpm.
Unit
rpm
Modify acceleration of a sequence
Instruction UA
Parameters
1st parameter: sequence number.
2nd parameter: acceleration time.
If there is no 2nd parameter, the amplifier will return the actual acceleration time of the
sequence
(1st
parameter).
Conditions
This instruction can be sent only if no sequence is executed.
The sequence must exist.
Unit
Millisecond
Range
16 ms - 16000 ms
Remark
The parameters
acceleration time
and
deceleration time
define the time with regard to the
maximum speed parameter value. When the motion speed is lower than the maximum speed,
the trajectory acceleration and deceleration times are proportionally reduced.
Modify deceleration of a sequence
Instruction UD
Parameters
1st parameter: sequence number.
2nd parameter : deceleration time.
If there is no 2nd parameter, the amplifier will return the actual deceleration time of the
sequence
(1st
parameter).
Conditions
This instruction can be sent only if no sequence is executed.
The sequence must exist.
Unit
Millisecond
Range
16 ms - 16000 ms
Remark
The parameters
acceleration time
and
deceleration time
define the time with regard to the
maximum speed parameter value. When the motion speed is lower than the maximum speed,
the trajectory acceleration and deceleration times are proportionally reduced.