CHAPTER 2 – Specifications
SMT-BD2/m
3.2
-
F
USE PROTECTION
3.2.1 - Fuse protection for the 220 VAC amplifier version
F1 : Control of the average DC current of the power board supply (
see Hardware adjustments in chapter 5
).
F2 : Control of the average DC current of the logic board supply (
see Hardware adjustments in chapter 5
AMPLIFIER TYPE
F1
F2
Power
Logic
SMTBD2/m-220/04 to 12
10 AT
1 A
SMTBD2/m-220/17 and 30
15 AT
1 A
SMTBD2/m-220/45
20 AT
1 A
SMTBD2/m-220/60
20 AT
1 A
SMTBD2/m-220/70
-
1 A
SMTBD2/m-220/100
-
1 A
3.2.2 - Fuse protection for the 400 VAC amplifier version
F2 : Control of the average DC current of the logic board supply (
see Hardware adjustments in chapter 5
).
AMPLIFIER TYPE
F2
Logic
SMT-BD2/m - 400/15
1 A
SMT-BD2/m - 400/30
1 A
SMT-BD2/m - 400/45
1 A
SMT-BD2/m - 400/60
1 A
SMT-BD2/m - 400/100
1 A