![Infranor SMT-BD2/m Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/infranor/smt-bd2-m/smt-bd2-m_manual_2058381043.webp)
43
CHAPTER 7 – Programmation
SMT-BD2/m
Reset counter/Modulo
: this function allows to reset the position counter when it reaches a pre-defined value. If
the value is set at 0, this function is not activated.
Forward
: when the function
Reset counter/Modulo
is activated, if
Forward
is selected (ticked off), the motor
runs only in the positive direction for an absolute displacement lower than the value of the
Reset counter
parameter. When the function
Reset counter/Modulo
is activated, if
Forward
is not selected (not ticked off), for
an absolute displacement lower than the value of the
Reset counter
parameter, the motor follows the shortest
way.
Software limit sw and -
: this function is only active if the HOME sequence has been previously
executed. When the motor passes the software limit position value, it is stopped with a controlled braking. The
deceleration ramp value is given by the jog deceleration time.
3.3
-
POSITIONER
CONFIGURATION
Speed profile
: trapezoidal or S-curve shape selection.
Analog input limitation
: enables the motor speed limitation by the analog input on pin 17 of the X4 connector.
The axis displacement speed is then limited with regard to the programmed speed value. For the TORQUE,
SPEED and positioning sequences (ABSOLUTE or RELATIVE), the programmed speed can be continuously
modified according to the analog input voltage value, if
speed modulation
is selected. For the HOME sequence,
the programmed speed is limited during the entire sequence execution according to the analog input voltage value
at the sequence starting. The speed reduction can be proportional or inversely proportional to the analog input
value according to the
reversed limitation
parameter.
Reversed limitation
: defines the polarity of the speed limitation with regard to the analog input voltage value. The
reversed limitation activation allows to get the speed limitation proportional to the analog input value. When
reversed limitation is not selected, the speed limitation is inversely proportional to the analog input value (for 0 V,
the motor runs at the programmed speed and for 5 V the motor runs at half of the programmed speed).
Speed modulation
: enables the continuous modulation of the motor speed according to the analog input voltage
value during a TORQUE, SPEED or positioning (ABSOLUTE or RELATIVE) sequence execution. When
speed
modulation
is disabled, the programmed speed is limited during the entire sequence execution according to the
analog input voltage value at the sequence starting.
Input filter
: defines the cut-off frequency value for the low pass filter on the analog input (pin 17 of X4).
Brake ON delay
: defines the time between the brake activation and the amplifier disabling according to the
following timing:
- brake ON (contact open),
- delay time,
- amplifier disabled.
The brake ON delay value must be higher than the brake response time.
Brake OFF delay
: defines the time between the amplifier enabling and the brake desactivation according to the
following timing:
- amplifier enabling,
- delay time,
- brake OFF (contact closed).
The brake off delay value must be higher than the amplifier servo loop response time.
Minimum SEQ pulse
: when activated, this function defines the minimum duration of the SEQ output. This
function is useful for the detection of a sequence with a short duration.
InPos window
: when activated, this function defines the position window in which the
POS
output is activated:
window = arrival po/- programmed value. This parameter is only valid for a positioning sequence. If this
function is not enabled, the
POS
output is activated at the end of the position trajectory regardless of the real
position value.
Digital CAM
: when activated, this function activates the logic output OUT1 when the motor passes an area
defined by positions P1 and P2.
OUT1 output
Position P1
Position P2
Motor position :