SMT-BD2/m
CHAPTER 9 – Appendix
Execution of a sequence
Instruction GO
Parameters
1st parameter : sequence number.
Conditions
This instruction can be sent only if no sequence is executed.
"Enable" and "Run" signals are activated.
"Wait" and "Stop" inputs are not activated.
The sequence must exist.
Remark
This instruction executes a sequence (with parameter as sequence number) regardless of the
logic
inputs
status.
Position feedback
Instruction PF
Parameters none
Conditions Read
only
Remark
This instruction reads the position of the motor.
Unit
Inputs/Outputs status
Instruction IO
Parameters None
Conditions Read
only
Remarks
This instruction reads the logic inputs and outputs status
bit meaning
0 START
1
STOP
2
WAIT
3
TEACH
4
JOG+
5
JOG-
8
SEQ
9 POS
10
SPEED
11
OK
16
IN1
17
IN2
18
IN3
19
IN4
20
IN5
21
IN6
22
IN7
23
IN8
24
OUT1
25
OUT2
26
OUT3
27
OUT4
28
OUT5
29
OUT6
30
OUT7
31
OUT8
- Bit SEQ indicates that the positioner is running a sequence.
- A sequence can be executed when bit OK is set and bit STOP is reset, and also if the security
of the first sequence (HOME) is disabled.
Absolute move
Instruction MP
Parameters absolute
position
Conditions
"Enable" and "Run" signals are activated.
Remark
Unit