4. Insert the replacement module. Make sure the extraction handle is held at its
highest position so that the saddle notches on the sides of the handle can snap
onto the metal anchor pins placed along the interior walls of the PSU slot. Push
the PSU into chassis, and when you feel the contact resistance, use slightly
more force to engage the back-end connectors. Push the handle downwards to
secure the module.
1U systems
2U systems
5. Fasten the retention screw.
6. Reconnect the power cord.
7. Power on the PSU module.
WARNING!
When a PSU is removed form the chassis, the cooling module is also removed from
the chassis. Hence the airflow provided by the cooling module is also disabled.
With an empty module bay, airflow will also be disrupted. It is therefore
recommended the replacement procedure is completed in less than five (5)
minutes to prevent the system from overheating.