EonStor DS B12/B24 Series
8.
For single controller models or when replacing both controllers
simultaneously, power up the system
.
Check system message on the LCD
screen, SANWatch, or firmware menu-driven utility. When the replacement
controller is successfully brought online, the
should turn
on properly.
9.
For single controller models or replacing both controllers simultaneously
,
Restoring NVRAM data.
To restore previous ID/LUN mapping settings, users
may use the following options:
Use the “
Restore NVRAM from Disks
“or “
Restore NVRAM from
Files
” functions in the firmware. ID/LUN mapping will be restored.
Or
Use the LCD panel to restore ID/LUN mapping settings (refer to the
illustration below).
RAID model No.
Ready
Ent
Ent
Ent
Ent
Import NVRAM
include password?
except password?
Ent
Import NVRAM
in progress
View and Edit
Logical Drives
System
Functions
Import NVRAM from
reserve space
Export NVRAM to
reserve space
Mute Beeper
Controller
Maintenance
Legend
Ent: Press the Enter (Ent) button.
Ent
: Press and hold the Enter (Ent) button for 2 seconds.
---->
:
Press the up and down arrow to scroll to the menu you are after.
120