of AC input
I
2
C
Through backplane to RAID controller(s)
Over-temperature
Protection
Auto shutdown when losing cooling or elevated
ambient temperature; over-voltage protection is
also available.
Cooling Fans
No fans specific for PSU; heated air is drawn by
the cooling fan module fixed in the rear section of
PSU.
A.4
Cooling Module Specifications
Specifications
Speed
High or low rotation speed controlled by
firmware’s proactive mechanisms
Max. Air Flow (each
module)
High speed: 90CFM
Low speed: 70.7CFM
Input Power
13.2W max.
Input Current
1.1A max.
Rated Voltage
DC 12V
Temperature
Operating: -10 to +70ºC
Storage: -30 to +70ºC
Noise
51dB (high speed); 46dB (low speed)
A.5 RAID
Management
Specifications
Configuration
•
Text-based firmware-embedded utility
over RS-232C through the included serial
cable; Y-cable for the dual-controller
model.
•
LCD
keypad
panel
•
The RAIDWatch Manager program using
in-band or Ethernet connection
Performance
Monitoring
Yes
Remote Control
and Monitoring
Yes
Event
Broadcast/Alert
Yes, (via RAIDWatch sub-module, the
Configuration Client utility, NPC, or
Embedded browser-based RAIDWatch)
Event Notification
Yes, (via RAIDWatch sub-module, the
Configuration Client utility, NPC, or
Embedded browser-based RAIDWatch)
Hardware
Connection
In-band over SAS, out-of-band via Ethernet or
RS-232C