Chapter 3: Subsystem Connection
Figure 3-6: Connecting SFP Transceiver and LC Type Cables
Step 7.
Remove the protective caps on the other end of the
cable and connect this end to an SFP transceiver
module on a Fibre Channel switch port or a Fibre
Channel host bus adapter (HBA) port.
3.4 Expansion Links
Expansion enclosures are connected with the subsystem through the
“
SAS Exp.
” ports. Please see below for matching RAID and JBOD
and required cables.
RAID Models
2U JBOD
Required Cables
(between RAID
and JBOD)
Required Cables
(between JBODs)
S12F-R1432
S12S-J1002-R
SFF-8088 to SFF-
8088
SFF-8088 to SFF-
8088
S12F-G1433
S12S-J1000-G
SFF-8088 to SFF-
8470
SFF-8470 to SFF-
8470
3.4.1
Expansion Configuration
3.4.1.1 Redundant-controller RAID to Redundant-
controller JBODs
The redundant-controller model, S12F-R1432, can connect up to 3
JBODs.