background image

1-4

Chapter 1: Product introduction

1.3 

Front panel components

This section describes the components of GSe Pro 100 system’s front panel components.

1.3.1  LED panel

The LEDs on the panels allow you to know your system’s current status when in operation.

NOTE:

 For more details regarding the LEDs and their respective status, refer to 

3.1.1 LEDs

.

1.2.3  Side panel

Number

Part

Description

11

DIMM slots

These slots accommodate two DDR3 SO-DIMMs.

11

Flash module

This module serves as a cache backup and also contains NAS OS.

Number

Part

Description

11

System status

This LED provides the status of the system.

11

Fan status

This LED provides the status of the system’s fan.

11

Temperature 

status

This LED provides the system’s temperature status.

WARNING!

  DO NOT remove the flash 

module. If you want it replaced, call 

your local dealer or technical support.

Содержание EonStor GSe Pro 100

Страница 1: ...EonStor GSe Pro 100 Series Hardware Manual...

Страница 2: ...rt for assistance To the extent permitted by applicable laws Infortrend shall NOT be responsible for any interoperability or compatibility issues that may arise when 1 products software or options not...

Страница 3: ...cedures 2 2 2 2 1 Unpacking the system 2 2 2 2 2 Preparing for the installation 2 2 2 2 3 Installing the hard drives 2 3 2 2 4 Installing a host expansion board 2 7 2 3 Connections 2 9 2 3 1 Connectin...

Страница 4: ...Certifications A 1 Safety and warning clauses A 2 User warning A 2 UL caution safety and warning markings A 2 Declaration of the presence condition of the restricted substance marking A 3 Contact inf...

Страница 5: ...tested before turning on the system If the system is not used for a long period disconnect it from the power outlet to avoid transient over voltage Service and maintenance Keep the faulty hard drive i...

Страница 6: ...T remove the hard drives from their anti static bags before the installation DO NOT stack the drives on top of each other without their protective drive trays Even if the drives are fixed to the drive...

Страница 7: ...vii Revision history Version Date Description 1 0 February 2019 Initial release...

Страница 8: ...x 1 Gb s iSCSI ports 4 x 8 Gb s FC ports Fiber channel 4 x 10 Gb s iSCSI ports SFP NOTE Fibre channel supports point to point and switch mode USB connectivity 2 x USB 2 0 ports 2 x USB 3 0 ports Driv...

Страница 9: ...sync Snapshot 64 per volume 128 per system Block level local replication Replication pairs per source volume 4 Replication pairs per system 16 Optional software features Automated tiering 2 tiers Adva...

Страница 10: ...e environment is not supported currently Note Download GSe Pro Compatibility Matrix for the latest OS support details Service and support Standard services 3 year limited hardware software warranty 8...

Страница 11: ...Group management Folder management Folder and sub folder access control Folder quota Comprehensive access control action items All controls Read Read and Run Modify List Support Windows Active Direct...

Страница 12: ...your system NOTE The contents and quantity may vary depending on the system model and order requests System package GSe Pro 100 Series system Quick installation guide 3 5 inch HDD screws 2 5 inch HDD...

Страница 13: ...m comprised of hot swappable hard drives and constructed in a rugged aesthetic This series comes in two models GSe Pro 105 and GSe Pro 108 Both models support RAID 0 1 5 and 6 hard drive configuration...

Страница 14: ...s rugged storage chassis 1 2 1 Front panel EonStor GSe Pro 105 EonStor GSe Pro 108 Number Part Description 11 LED panel LED panel has HDD cooling fan and thermal LEDs 11 Power button This button allo...

Страница 15: ...using Kensington security devices 11 1 GbE RJ 45 ports These 8 pin ports support a standard Ethernet cable to connect to a local network 11 USB 3 0 ports These USB ports provide a transfer rate of up...

Страница 16: ...refer to 3 1 1 LEDs 1 2 3 Side panel Number Part Description 11 DIMM slots These slots accommodate two DDR3 SO DIMMs 11 Flash module This module serves as a cache backup and also contains NAS OS Numbe...

Страница 17: ...ives and 3 5 inch HDD hard disk drives Get familiarized of the components of the drive tray bezel Number Part Description 11 Release button This button unlocks the drive tray from the drive tray slot...

Страница 18: ...l that allows you to connect to GSe Pro 100 system and a series of JB 208 systems Number Part 11 Power socket 11 Kensington lock 11 SAS expansion port status LEDs 11 Rotary ID switch 11 SAS expansion...

Страница 19: ...ument is included in the package If there are items missing and or damaged contact your vendor for a replacement Hard drives The SATA drives are purchased separately and must be available before the s...

Страница 20: ...with in your package Accessory box contents This box contains the following RS 232C serial cable mini USB to DB 9 cable Screws for 2 5 and 3 5 inch drives Quick installation guide EonOne Quick Start G...

Страница 21: ...common denominator approach which means that the maximum capacity used in each drive to comprise a logical configuration is the maximum capacity of the smallest drive We strongly suggest to use large...

Страница 22: ...ause it helps you identify the faulty drive Take a look at the table below of the fault tolerance of different RAID levels RAID Minimum disk requirement Maximum number of failed drives without data lo...

Страница 23: ...s that are bundled in the system package Securing the drives with longer screws may damage them WARNING Be careful not to drop or put heavy objects on the drive tray as these may cause to bend or defo...

Страница 24: ...occupied with the drive trays even if there are no hard drives installed Without the drive trays the ventilation is compromised and may cause overheating Once all drives are installed the system reco...

Страница 25: ...stall a host expansion board NOTES A downtime may occur when you install or replace the host expansion board To add or replace a host board the firmware automatically restores the default factory sett...

Страница 26: ...ation 3 Orient and slide the host expansion board into the host expansion board slot 4 Turn the host expansion board s knobs clockwise to secure the host expansion board to the system NOTE Keep the du...

Страница 27: ...1 or 2 and 3 to boost the bandwidth You can also create pools and folders to share over the network To do these refer to EonStor GSe Pro Software Manual for a more detailed configuration For physical...

Страница 28: ...nd must be handled with care DO NOT bend or twist the cables when connecting between systems Setting the expansion IDs Each expansion system must have a unique ID and you can configure the ID via the...

Страница 29: ...l components are properly installed and the management interfaces are properly connected Take a look at the list below and check the following 1 The drives are correctly installed to the drive trays 2...

Страница 30: ...orking devices 2 Turn on the JBOD expansion systems 3 Press the power button on the front panel 4 Turn on the application servers NOTES The NAS server operates using DHCP Dynamic Host Configuration Pr...

Страница 31: ...e system status via the following interfaces Front panel LEDs NOTE Refer to chapter System maintenance for more information regarding the LED description 2 3 5 Turning off the system Press and hold th...

Страница 32: ...mware The firmware manages the controllers of the system which is accessible in a terminal program via the serial port For more details see the firmware manual in the bundled CD EonOne EonOne is a bro...

Страница 33: ...down The device encounters critical error s OFF The system is off 11 Fan The system fan s is are running normally A fan failure occurred 11 Temperature The internal temperature is normal and within th...

Страница 34: ...e message you must check the drive tray LEDs to find the correct location of the failed drive Number LED name Color Description 11 Power status The drive bay is occupied and working normally Disk driv...

Страница 35: ...nnection is established Data I O is ongoing OFF No connection is established 11 Speed 1 Gb connection is established OFF 10 100 Mb or no connection is established When you restore the system to its de...

Страница 36: ...Memory modules Host expansion board Hard disk drives WARNING DO NOT remove a defective component from the system until you have the replacement on hand Doing so may disrupt the internal airflow Consu...

Страница 37: ...ct your system vendor to help you purchase the compatible modules NOTE Refer to section ESD precautions for safety information To replace the memory module 1 Shut down your system Wait for a minute fo...

Страница 38: ...onStor GSe Pro 100 Series Hardware Manual 4 Insert the new or replacement memory modules to the DIMM slots 5 Slide the cover back to the system A then secure it with the two screws you removed in step...

Страница 39: ...s the system to its factory settings when you add or replace a host expansion board Contact your system vendor to help you purchase the compatible host expansion boards To replace the host expansion b...

Страница 40: ...o 100 Series Hardware Manual 3 Orient and slide the replacement host expansion board into the host expansion board slot 4 Turn the host expansion board s knobs clockwise to secure the host expansion b...

Страница 41: ...terface connectors To replace the hard drives 1 Identify the faulty hard drive using the EonOne software NOTE See section Hard drive designation for the order of the drive bays 2 When the faulty hard...

Страница 42: ...drive associated with host ID LUN To restore the default settings 1 Stop all input output activities 2 Save the current configuration using Export NVRAM 3 Turn off the system 4 Insert a straightened p...

Страница 43: ...cond Edition Am 1 2009 Am 2 2013 EAC TP TC 004 2011 TP TC 020 2011 EMC CE EN 55032 2012 AC 2013 EN61000 3 2 2014 EN 61000 3 3 2013 EN 55024 2010 A1 2015 BSMI CNS 13438 FCC FCC Part 15 subpart B Enviro...

Страница 44: ...b timent en vigueur WARNING Interconnection of more than one power supply source to a section of grid rail bus may present a fire hazard AVERTISSEMENT Interconnexion de plus d une source d alimentatio...

Страница 45: ...ply Hard disk Power cable Fan 1 0 1 wt 0 01 wt Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted substance exceeds the reference percentage value of...

Страница 46: ...ddress 435 Lakeside Dr Sunnyvale CA 94085 USA Telephone 1 408 988 5088 Fax 1 408 988 6288 Email sales us infortrend com Website https www infortrend com us Home Support http support infortrend com Acc...

Страница 47: ...end com Website https www infortrend com uk Home Support http support infortrend com Account Logon Infortrend worldwide sales offices Spain and Portugal sales offices Email sales es infortrend com cs...

Страница 48: ...com pl Home Support http support infortrend com Account Logon Middle East sales offices Email sales meat infortrend com Website https www infortrend com ae Home Support http support infortrend com Ac...

Отзывы: