3-5
EonStor GSa 3000 Series Hardware Manual
•
1 G Ethernet management port LEDs
Number
LED name
Status
Description
11
Speed
ON
1 Gb connection is established.
OFF
•
10/100 Mb connection is established.
•
No connection is established.
11
Link/Active
ON
A connection is established.
Flashing
Data I/O is ongoing.
OFF
No connection is established.
•
12 G SAS expansion port LED
LED name
Status
Description
Link/Active
ON
All 4 PHY links are validly linked.
Flashing
Less than 4 PHY links are connected (at least one of the
PHYs has failed).
OFF
All 4 PHY links are offline.
•
10 G Ethernet port LEDs
Number
LED name
Color/
Status
Description
11
Speed
10 Gb connection is established.
1 Gb connection is established.
OFF
10/100 Mb connection is established.
11
Link/Active
ON
A connection is established.
Flashing
Data I/O is ongoing.
OFF
No connection is established.