EonNAS 1000 Series Hardware Manual
61
4.3 Replacing the Power Supply
Power supplies are redundant and load-sharing. PSUs are hot swappable!
Disconnect the power cord from the failed power supply. (Its LED should light static
Red).
Place your thumb around the left side of the PSU ejection lever (circled in
red
) while
hooking your index and middle finger around the PSU handles (circled in
blue
).
Use your thumb to push the lever in the direction of arrow (shown below) to disengage
the power supply and use your index and middle finger hooked around the ejection
lever to pull out the PSU.
To install the replacement module, make sure it is gently inserted and is pushed all the
way in.
Connect the power cord, power on, and check if the LED lights static Green.
WARNING
Ensure both PSUs are plugged-in and operational at all times. Should one fail,
please organize a replacement unit immediately!