57
3. User Password Change
Click
button in the account list, the dialog box of Edit User Information
will pop up:
Figure 4-49
Input the old password, enter the desired new password for twice and then click
“OK” button, the following picture will appear:
Figure 4-50
4.10 System Log
Click the “Log” option tab, the date, time and log information will appear on
the right of the screen.
58
Figure
4-51
It can display 30 logs on a page. The user can turn over the pages or skip to the
desired page by clicking the below arrows. Click “Delete logs”, a prompt will
come out. Then, click “Yes” to clear logs.
59
APPENDIX I MAGNETIC RING FILTER INSTRUCTION
To reduce electromagnetic interference that power supply generates, it is
necessary to install a magnetic ring filter with the power cable of Infinova
front-end IP device.
To install a magnetic ring filter with power supply:
Step 1:
Open the magnetic ring filter and lead the power cable through.
Step 2:
Wire the power cable on the magnetic ring filter 3 rounds or more
(Make sure the filter can be well closed).
Step 3:
Close the magnetic ring filter.
Notice:
The magnetic ring filter should be installed no more than 50 mm
away from the power output connector. As shown in Figure 3, the cable
length from A to B should be 50mm at most.
Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter
Figure 3 Power cable with magnetic ring filter
60
APPENDIX II QUESTIONS & SOLUTIONS
The following table describes the symptoms causes and solutions for the
problems.
Symptoms
Possible Causes
Solutions
The network
camera does
not perform
initiation after
power-on
Wrong power connection
Reconnect power cable
Power supply failure
Repair or replace power
supply
PCB fuse damage
Replace the fuse
Immediate startup after
power-off
Restart 10 seconds later
after power-off
If PoE power supply is used,
too long transmission distance
may make the power of the
Power Supply Switcher
insufficient.
Shorten the length of the
power supply network
cable, or replace Power
Supply Switcher of larger
power
If PoE power supply is used,
connection to other electric
appliance make
s
the ground
level not in the correct level.
Disconnect other electrical
appliance.
No video signal
displayed
The plug-in for viewing image
is installed incorrectly.
Refer to the Plug-in
Installation to reinstall it.
Network camera’s IP address
conflicts with other user’s IP
address
Set the unique IP address
Vague image
Manual focus is not precise
Manually adjust the camera
focus carefully.