130
Infinity Chimp Series
Infinity Chimp Series
Loading all Effects without Base Values from Current Output
To grab all values that are currently being output for the selected fixtures, hold down the
[Load]
key
and press the
[FX]
key simultaneously.
This will grab all Effect values currently being output from the console’s playback engine.
Loading Values from a Cuelist
You may load a stored cue to modify it. Please see working with Cuelists for more Info.
Working with individual Timings
By selecting the
Timing
button from the Programmers title bar, the programmer switches into Timing
Mode. In timing mode you can select all attributes as usual and assign individual times to them just like
any other value.
Individual Timings can also be fanned using the Fan function (also in conjunction with Grouping and
Buddying).
Switching into Timing Mode inside the Programmer will automatically switch Fanning Mode to "Fan Left".
Previous Mode will be restored when Timing Mode is turned off again.
Individual Fade and Delay times will override general Cue timings. For each value inside a Cue the timing
will be determined in the following priorities:
Priority
Highest
Individual Parameter Timings
Parameter Group Timings (as defined in the Cuelist View)
Lowest
Cue Infade/Outfade Timing
In case of using MiB feature for values which have been programmed with individual Fade and Delay
times these timing will not be replaced by MiB timings. MiB for these values will be applied using the
individual Fade and Delay Timnings programmed.
Fig. 101: Timing Button in Programmer Title Bar
Individual Fade Times