129
Infinity Chimp Series
Infinity Chimp Series
Setting All Fixture Attribute Values to the Fixtures default value
Sometimes it may be useful to set a fixture to its default values that are defined in the library and pull all
values into the programmer.
In order to so press the
[Home]
key on the console’s faceplate.
Using Presets (as a reference)
You may also use a previously stored Preset to recall values that use the preset as a reference. Please see
“Working with Presets” for more information.
Using Values (instead of referencing) from a Preset
In case you do not wish to load a preset as a reference, but rather as hard values, please see “Working
with Presets” for more information.
Loading Values from other sources
Loading all Values from Current Output
To grab all values that are currently being output for the selected fixtures (including the default values),
hold down the
[Infinity]
key and press the
[Load]
key simultaneously.
This will grab all values from the console’s playback engine, but before any Group or Fixture Master
Dimmers are calculated.
In Example: Your fixture is programmed in a cue that is played back with an intensity of 100%, however
you have a master dimmer set for this fixture at 50%. When you grab the fixtures values, the console will
load the value at 100% into the programmer, since this is the playback engines value for the fixture.
Loading all Values for a specific Attribute Group from Current Output
To grab all values that are currently being output for a specific attribute group for the selected fixtures
(including the default values), press the
[Load]
key and press the desired function groups softkey from
the programmer side menu.
This will grab all values for the selected Fixtures for the selected attribute group from the console’s
playback engine, but before any Group or Fixture Master Dimmers are calculated.
In Example: Your fixture is programmed in a cue that is played back with an intensity of 100%, however
you have a master dimmer set for this fixture at 50%. When you grab the fixtures “intensity” attribute group
values, the console will load the value at 100% into the programmer, since this is the playback engines
value for the fixture.
Loading all Values without Effects from Current Output
To grab all values that are currently being output for the selected fixtures, hold down the
[Load]
key
and press the
[Fixtures]
key simultaneously.
This will grab all values from the console’s playback engine, except the Effect Values.