LT5889 issue 7(10/12)

 

 

 

600 CF 

Users Instructions

 

 

SECTION ONE 

Introduction Continued 

 

 

Care  must  be  taken  to  prevent  any  damage  being  caused  to  surrounding  soft  furnishing  or 
decoration; e.g. many embossed vinyl wall coverings may become discoloured if placed too close 
to  the  appliance.  Combustible  material  i.e.  wall  panelling  or  wallpaper  must  be  removed  from 
behind the fire and fire trim.  

 

It  is  advised  that  this  appliance  is  serviced  annually;  as  it  is  more  likely  to  provide  trouble-free 
operation. 

 

In  GB  (Great  Britain)  the  fire  does  not  normally  require  purpose  built  ventilation,  but  if  for  any 
special  reason  purpose  built  ventilation  is  provided  it  should  be  checked  periodically  to  ensure 
freedom from obstructions.  

 

In IE (Ireland) permanent ventilation must comply with the current edition of IS813. 

 

SECTION TWO 

Operating the Appliance

 

 
To light the appliance using the remote hand set:

 

a.  Point  the  remote  control  hand  set  in  the  direction  of 

the  appliance  and  press  the 

  button.  Continue  to 

hold  the  button  for  approximately  2  seconds  and 
release. When released a bleep should be and heard 
the appliance will automatically go through the ignition 
sequence and the pilot should ignite. Once the pilot is 
alight  the  appliance  will  automatically  go  to  the  high 
setting (approximately 20-25sec).  

b.  If  the  ignitor  stops  sparking  and  the  pilot  fails  to  light 

press  the 

  button  for  at  least  2  seconds  and 

release,  again  a  bleep  should  be  heard.  Then  repeat 
the lighting procedure.

* see note on page 7

 

c.  With the appliance lit, by pressing 

 key the operational mode is switched from manual to Room 

thermostat setting and vice versa. When Room thermostat mode is active, the display shows the 

set temperature value and the “AUTO” icon will appear on the LCD display. By using the

  arrow 

key the desired room temperature can be set.  When manual mode is active, the display shows 

the “MAN” icon plus the flame icon and a five level bar icon setting. By pressing the 

 arrow key, 

the flame picture can be adjusted at five stages between high and low flame. If level 5 is currently 

active, the icon max  

 below the flame icon will appear.   

*Note: Due to the nature of the gas,  

flame variation on LPG models will only be visible on Hi and Lo setting*

 

d.  To switch off the appliance press the 

 button for at least 2 seconds and on releasing the button 

the appliance will bleep and then shut off.  

e.  The appliance can be switched off with out using the hand set by removing the appliance batteries 

located  below  the  air  grill  cover.  When  the  batteries  are  removed  there  will  be  a  delay  (up 
3minutes) after which, double bleeps may be heard and shortly after the appliance will extinguish. 
Ensure that the battery is reconnected once the fire as been extinguished.  The appliance cannot 
be operated without the use of the handset. 

Room Thermostat mode 

The remote handset checks the room temperature at a fixed time intervals. Depending on the 
difference between set room temperature and the actual room temperature the remote proceeds to 
modulate in one level steps. Once the room temperature is reached it moves to standby position pilot 
 Only. 

Содержание 600 CF

Страница 1: ...TIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is For use in Great Britain or IRELAND on...

Страница 2: ...panel 10 INSTALLATION INSTRUCTIONS SECTION FIVE Appliance Data 12 SECTION SIX Regulations and Warnings 13 SECTION SEVEN Siting the Appliance Flue Class1 14 Installation Compatibility plinth hole in w...

Страница 3: ...ervicing installation it is recommended that it is of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped i...

Страница 4: ...REGULATIONS The Building Regulations or The Building Regulations Scotland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the applian...

Страница 5: ...the lighting procedure see note on page 7 c With the appliance lit by pressing key the operational mode is switched from manual to Room thermostat setting and vice versa When Room thermostat mode is...

Страница 6: ...g pressed key at least for 5 seconds the temperature unit changes from Celsius to Fahrenheit degrees and vice versa Battery level indication Handset When the batteries have to be changed in the handse...

Страница 7: ...emove the battery holder from within the protective cover and replace the six high power alkaline C batteries as a complete set WARNING batteries will overheat if fitted incorrectly when fitting the b...

Страница 8: ...his may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From time to time it will be necessary t...

Страница 9: ...nts provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on...

Страница 10: ...aning and Layout Continued Fuel Bed Layout LOG Locate air tray within the slot on shelf assembly Place 1 2 Log Shapes to the front of the Stainless Steel Burner Place a thin layer of Vermiculite on to...

Страница 11: ...00 CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Fuel Bed Layout LOG Place shapes 3 to 5 Log Shapes on top of the Air Tray as shown Bridge Log shapes 6 7 as shown Bridge Lo...

Страница 12: ...rigid or rigid Data Badge Location Located on the left hand side of the base of the appliance behind the trim Battery Remote handset 3 x AAA 1 5 V Appliance 6 x 1 5V C Cell high power alkaline NOTE T...

Страница 13: ...etent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if approp...

Страница 14: ...tion of natural draught Ensure that the air entering the appliance below the lower edge of the decorative trim is not restricted If the appliance is fitted above a forward projection hearth the base o...

Страница 15: ...mble in reverse order Ensure that the trim is the correct orientation CONNECTING THE GAS SUPPLY Note An isolation valve may be fitted in the gas supply adjacent to inlet pipe For a concealed connectio...

Страница 16: ...ce located on page 3 of this booklet before laying or replacing any refractory material In the event of replacing fuel bed components please use only the specified number of components as illustrated...

Страница 17: ...vertical side flange of the box Avoid placing magnets along the top section of the trim Offer the decorative trim up squarely and centrally and push into position To remove the decorative trim simply...

Страница 18: ...and glass assembly Section 3 Remove the loose fuel bed components Disconnect battery leads and remove appliance battery Remove the fixing screw from the EDB fixing bracket Detach remote control eye f...

Страница 19: ...end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Remove the fixin...

Страница 20: ...ust be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the user s instructions 3 The appliance must be serviced annually by a Gas Safe registered person 4 The...

Страница 21: ...helpdesk Model Infinity 600 CF Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the left hand side of the base of the appliance...

Страница 22: ...e of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration N...

Страница 23: ...LS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model INFINITY 600 CF Serial No Date of Purchase This information can be found...

Страница 24: ...Glass Panel 600 CF Log set Containing 1x bag vermiculite Part No 5902 Silicone Sealing Strip 4818 AAA Battery 3 Remote Control Hand Set Restrictor Plate Part No 5990 Handset Holder 5910 Battery Holde...

Отзывы: