Infinity 600 CF Скачать руководство пользователя страница 3

LT5889 issue 7(10/12)

 

 

 

600 CF 

Users Instructions 

 

SECTION ONE 

Introduction

 

 

Consumer Protection Information 

As  manufacturers  and  suppliers  of  heating  products,  we  take  every  care,  as  far  as  is  reasonably 
practicable,  that  these  products  are  so  designed  and  constructed  as  to  meet  the  general  safety 
requirement  when  properly  used  and  installed.  To  this  end,  our  products  are  thoroughly  tested  and 
examined before despatch. 

IMPORTANT  NOTICE:

  Any  alteration  that  is  not  approved  by  the  appliance  manufacturer  could 

invalidate  the  approval  of  the  appliance,  operation  of  the  warranty  and  could  affect  your  statutory 
rights.

 

 

Health and Safety Notice 

Important 

This appliance could contain some of the materials, indicated below, that could be interpreted as 
being injurious to health and safety. It is the users / installers responsibility to ensure that the 
necessary personal protective clothing is worn when handling these materials, see below for 
information. 

Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yarn - 

may 

be harmful if inhaled, may be irritating to skin, eyes, nose and throat.  

When handling,

 

avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks and 

eye protection. After handling wash hands and other exposed parts. If a vacuum is used for cleaning 
the coals or cleaning after servicing / installation it is recommended that it  is of the type fitted with a 
HEPA filter. 

Disposal of refractory / ceramic materials

. To keep dust to a minimum these materials should be 

securely wrapped in polythene and be clearly labelled ‘RCF waste’. These materials are not classified 
as ‘hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste. 

 

 

INTRODUCTION 

 

The 600 CF as been designed and tested to the requirements of EN 613 and is suitable for use in 
GB (Great Britain) and IE (Ireland). 

 

The  600  CF  incorporates  a  single  gas  control,  which  selects  ignition  pilot,  with  variable  setting 
between  low  and  high  settings  and  is  operated  via  remote  control.  The  system  is  powered  by  a 
battery pack; therefore no mains electrical supply is required.  

 

Like all appliances incorporating an aerated burner a low frequency noise may be heard, this may 
be more noticeable on the low setting.

  

 

The 600 CF incorporates a safety device in the form of an Oxygen Depletion System, which 
constantly monitors the oxygen in the room and will cause the fire to switch off if the oxygen level 
reduces, for instance due to insufficient ventilation or a blocked flue.  
If this regularly occurs do not attempt to relight the appliance until a qualified engineer has 
checked it, the problem may not be due to lack of air or a defective flue. 

 

The pilot can be left on (standby setting) or the pilot can be extinguished and relit each time the 
fire is used. 

 

 

To obtain an authentic fire sound, a noise will be noticeable from the burner. 

Содержание 600 CF

Страница 1: ...TIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is For use in Great Britain or IRELAND on...

Страница 2: ...panel 10 INSTALLATION INSTRUCTIONS SECTION FIVE Appliance Data 12 SECTION SIX Regulations and Warnings 13 SECTION SEVEN Siting the Appliance Flue Class1 14 Installation Compatibility plinth hole in w...

Страница 3: ...ervicing installation it is recommended that it is of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped i...

Страница 4: ...REGULATIONS The Building Regulations or The Building Regulations Scotland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the applian...

Страница 5: ...the lighting procedure see note on page 7 c With the appliance lit by pressing key the operational mode is switched from manual to Room thermostat setting and vice versa When Room thermostat mode is...

Страница 6: ...g pressed key at least for 5 seconds the temperature unit changes from Celsius to Fahrenheit degrees and vice versa Battery level indication Handset When the batteries have to be changed in the handse...

Страница 7: ...emove the battery holder from within the protective cover and replace the six high power alkaline C batteries as a complete set WARNING batteries will overheat if fitted incorrectly when fitting the b...

Страница 8: ...his may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From time to time it will be necessary t...

Страница 9: ...nts provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on...

Страница 10: ...aning and Layout Continued Fuel Bed Layout LOG Locate air tray within the slot on shelf assembly Place 1 2 Log Shapes to the front of the Stainless Steel Burner Place a thin layer of Vermiculite on to...

Страница 11: ...00 CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Fuel Bed Layout LOG Place shapes 3 to 5 Log Shapes on top of the Air Tray as shown Bridge Log shapes 6 7 as shown Bridge Lo...

Страница 12: ...rigid or rigid Data Badge Location Located on the left hand side of the base of the appliance behind the trim Battery Remote handset 3 x AAA 1 5 V Appliance 6 x 1 5V C Cell high power alkaline NOTE T...

Страница 13: ...etent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if approp...

Страница 14: ...tion of natural draught Ensure that the air entering the appliance below the lower edge of the decorative trim is not restricted If the appliance is fitted above a forward projection hearth the base o...

Страница 15: ...mble in reverse order Ensure that the trim is the correct orientation CONNECTING THE GAS SUPPLY Note An isolation valve may be fitted in the gas supply adjacent to inlet pipe For a concealed connectio...

Страница 16: ...ce located on page 3 of this booklet before laying or replacing any refractory material In the event of replacing fuel bed components please use only the specified number of components as illustrated...

Страница 17: ...vertical side flange of the box Avoid placing magnets along the top section of the trim Offer the decorative trim up squarely and centrally and push into position To remove the decorative trim simply...

Страница 18: ...and glass assembly Section 3 Remove the loose fuel bed components Disconnect battery leads and remove appliance battery Remove the fixing screw from the EDB fixing bracket Detach remote control eye f...

Страница 19: ...end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Remove the fixin...

Страница 20: ...ust be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the user s instructions 3 The appliance must be serviced annually by a Gas Safe registered person 4 The...

Страница 21: ...helpdesk Model Infinity 600 CF Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the left hand side of the base of the appliance...

Страница 22: ...e of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration N...

Страница 23: ...LS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model INFINITY 600 CF Serial No Date of Purchase This information can be found...

Страница 24: ...Glass Panel 600 CF Log set Containing 1x bag vermiculite Part No 5902 Silicone Sealing Strip 4818 AAA Battery 3 Remote Control Hand Set Restrictor Plate Part No 5990 Handset Holder 5910 Battery Holde...

Отзывы: