SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
84
Revision 1.0, 2011-12-15
2.19.5
Outputs
2.19.6
Resource Usage
2.19.7
Execution Information
Table 86
IntervalTimerCalibration: Output values
Register/ Address
Type
Name
Description
R7
signed char
StatusByte
StatusByte:
0: Success
-1: No valid crystal frequency found in FLASH
-2: Input parameter out of range
Table 87
IntervalTimerCalibration: Resources
Type
Used or Modified
Registers
R0, R1, R2, R3, R4, R5, R6, R7
SFR
ACC, B, CFG0, DPTR, ITPH, ITPL, LFOOTP, PSW, TCON, TH0, TH1, TL0, TL1,
TMOD
Stack
2 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 88
IntervalTimerCalibration: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
1)
1) Values are obtained by extrapolation, not by characterization
t
12Mhz
–
1190
1680
µs
DIVIC = 00
H
, Clock Source is
12 MHz RC HF Oscillator
Execution Time
t
XTAL
–
1130
1570
µs
DIVIC = 00
H
Clock Source is XTAL
Charge
Consumption
Q
12MHz
–
1,23
2,56
µC
DIVIC = 00
H
, Clock Source is
12 MHz RC HF Oscillator
Charge
Consumption
Q
XTAL
–
1,60
3,04
µC
DIVIC = 00
H
Clock Source is XTAL