SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
33
Revision 1.0, 2011-12-15
Table 13
Meas_Pressure: Input Parameter: SensorConfig[15:8]
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
RES
RES
RES
RES
HYST
ARANGE
PRANGE
RAWTemp
RES
RES bits have to be set to 0
B
HYST
Select the thresholds for pressure hysteresis:
0
B
: Internal Configuration: 550kPa is the threshold from low to high pressure range
and 500kPa is the threshold from high to low pressure range.
1
B
: Customer Configuration - See (Pres3) and (Pres4)
ARANGE
Automatic range selection for pressure measurement:
0
B
: Manual
1
B
: Automatic
If compensation is disabled (SensorConfig.6[RAW]==.1) a manual pressure range
measurement is performed, using the range specified by SensorConfig.9[PRANGE].
Automatic Pressure Range is not supported for raw (uncompensated)
measurements.
PRANGE
Pressure range: (ignored if SensorConfig.10[ARANGE]==1)
0
B
: Low range (500kPa)
1
B
: High range (900kPa)
RAWTemp
Selects source of raw temperature data for compensation
0
B
: Perform new raw temperature measurement
1
B
: Use raw temperature data supplied in *(Pres2)