SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
102
Revision 1.0, 2011-12-15
2.28.6
Resource Usage
2.28.7
Execution Information
Table 123
FW_Revision_Nb: Resources
Type
Used or Modified
Registers
R0, R5, R7
SFR
ACC
Stack
2 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 124
FW_Revision_Nb: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
t
–
12
13
µs
Charge Consumption
Q
–
0,018
0,030
µC