SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
29
Revision 1.0, 2011-12-15
Charge Consumption in
autorange selection
Compensated with new raw
temperature measurement, 2
samples
Q
autpcomp,
new
–
1,643 2,515 µC
DIVIC = 00
H
,
SensorConfig = 0481
H
,
SampleRate = 00
H
Charge Consumption in
autorange selection
Compensated when supplied
with previously obtained raw
temperature value, 2
samples
Q
autocomp,
prev
–
1,196 1,869 µC
DIVIC = 00
H
,
SensorConfig = 0581
H
,
SampleRate = 00
H
Charge Consumption in
autorange selection for each
additional sample for
averaging
Q
autosampl
e
–
0,118 0,148 µC
SampleRate = 00
H
Only 1, 2, 4, 8, 16, 32, 64 samples possible
1) The execution time and charge consumption for automatic range selection have been verified when the proper pressure
range is selected.
Table 10
Meas_Sensor: Pressure Measurement: Execution Time and Charge Consumption
(cont’d)
Parameter
Symbol
Values
Unit Note / Test Condition
Min.
Typ.
Max.