SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
110
Revision 1.0, 2011-12-15
2.32.6
Resource Usage
2.32.7
Execution Information
Table 139
FlashSetLock: Resources
Type
Used or Modified
Registers
R0, R1, R2, R3, R4, R5, R6, R7
SFR
ACC, B, CFG1, CRC0, CRC1, CRCC, CRCD, DIVIC, DPH, DPL, TCON, TH1, TL1
Stack
8 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
RAM
2)
2) The FlashSetLock() overwrites RAM addresses 0x10 to 0x8F during its execution. For this reason it is recommended to
perform a software reset (CFG2.0[RESET] == 1) after this function returns.
0x10 to 0x8F
Table 140
FlashSetLock: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
1)
1) Values are obtained by extrapolation, not by characterization
t
–
116030 126010 µs
DIVIC = 00
H
Charge
Consumption
Q
–
291
404
µC
DIVIC = 00
H