SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
43
Revision 1.0, 2011-12-15
2.3.6
Resource Usage
2.3.7
Execution Information
Table 21
Scale_Pressure: Resources
Type
Used or Modified
Registers
R0, R2, R3, R4, R5, R6, R7
SFR
A, B, PSW
Stack
4 bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 22
Scale_Pressure: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
t
–
121
133
µs
DIVIC = 00
H
Charge Consumption
Q
–
0,188
0,317
µC
DIVIC = 00
H