INFICON
Operation | 6
UL6000-Fab,-PLUS-Operating-instructions-iinc75en1-01-(2206)
61 / 152
6.2.10 Set maintenance interval "Filter sniffer tip" or "Air filter"
To adjust the maintenance interval to the degree of contamination at the location of
the device, you can choose between a default value or a self-selected maintenance
interval.
ü
Supervisor
rights
1
> Setup > Maintenance counters
2
Adjust.
ð
Enter a value of your choice in hours for the "Filter sniffer tip" or press the
adjacent "Default value" button (1000 hours).
ð
Enter a value of your choice in hours for the "Air filter" or press the adjacent
"Default value" button (2500 hours).
3
Save
.
After performing a maintenance, you should reset the desired period until the next
maintenance.
See also
2
Change the filter mat inside the tool box [
2
Replacement of the filter mat on the bottom of the device [
2
Replacing the SL200 sniffer line filter [
2
Replacing the SL3000 sniffer line filter [
6.2.11 Activate or deactivate maintenance requests
Enables or disables warnings when the time for maintenance is exceeded. The time
until the next maintenance is displayed.
ü
Supervisor
rights
1
> Setup > Maintenance requests
ð
In the “Enable/disable maintenance requests” window, you can activate or
deactivate the maintenance requests for the following modules:
- Calibration leak
- TMP
- Filter sniffer tip
- backing pump
- Exhaust filter
- Air filter
2
Adjust.
3
Save
.
Содержание UL6000 Fab
Страница 2: ...INFICON GmbH Bonner Strasse 498 50968 Cologne Germany ...
Страница 125: ...INFICON Decommissioning 9 UL6000 Fab PLUS Operating instructions iinc75en1 01 2206 125 152 ...
Страница 145: ...INFICON Appendix 11 UL6000 Fab PLUS Operating instructions iinc75en1 01 2206 145 152 11 2 CE Declaration of Conformity ...
Страница 146: ...11 Appendix INFICON 146 152 UL6000 Fab PLUS Operating instructions iinc75en1 01 2206 ...
Страница 147: ...INFICON Appendix 11 UL6000 Fab PLUS Operating instructions iinc75en1 01 2206 147 152 11 3 RoHS ...
Страница 150: ...Index INFICON 150 152 UL6000 Fab PLUS Operating instructions iinc75en1 01 2206 Factory setting 70 ...
Страница 151: ......
Страница 152: ......