Characteristics 

Description

EN

Flood detector

Made in Czech Republic

• The fl ood detector is used to detect water leakage - the activation occurs the mo-

ment the fl ooding of the contacts located on the underside of the detector occurs.

•  Provides a quick solution to learn about unwanted fl ooding in your bathroom or 

kitchen that you can react too immediately.

•  With a wireless LoRa communication network the device can be immediately put in 

the desired location and run immediately.

•  Flood detection is signalled by vibration, optical and acoustic signalling. In the case 

of water detection, data is sent to the server, ...

•  Data is sent to the server from which it can be subsequently displayed as a smart-

phone, application, or Cloud notifi cation.

•  Anti-sabotage: If access to the device is unauthorized, a message is immediately 

sent to the server.

•  Power supply: 1x CR123A battery.

1. Vibrating motor
2. Battery
3. DIP switch
4. Hooter
5. Antenna
6. Probes pads

Underside view

Cloud app assignment

It is done in your Smartphone application. Enter the relevant information on the product 
cover into the application.

General instrucions

The front of the

detector

Seal

Function

The detector is designed to detect the presence of water in flooded areas such as cel-
lars, bathrooms, warehouses, etc. It is suitable for dealing with potentially recurring 
situations such as bath overflow, washing machine, dishwasher, boiler, blockages or foul 
waste, and floods due to groundwater, river or other emergencies.

Detector states

• 

Alarm - when the scanning contact is connected, the detector sends the data message 
and starts the set alarm. The signalling type can be set by the DIP switch. Signalling 
stops after 3 minutes even if the reason for the alarm has not been removed. In case of 
positive detection, the audible alarm is restored after 5 minutes.

• 

Terminate the alarm after a few seconds after the flood has dropped (disconnect the 
connection contacts).

• 

The  data  status  report  is  sent  at  twelve-hour  intervals  (can  be  edited  by  a  message 
from the server). In case of detection 2 seconds after connection of sensing contacts.

Commissioning

•  Remove the protective tape from the sensor contacts.

•  To activate the detector, place a conductive object (such as the included paper clips) on 

the sensing contacts. Hold for 20 seconds. The detector triggers a light and beep and 
sends an initial message.

• CAUTION: The fl ood detector detects only the presence of liquid that has reached the 

sensor. Liquid may be present in other areas.

•  Always be aware of potential dangers, develop safety awareness, and take precautions 

to avoid dangers whenever and wherever needed. The detector can reduce the likeli-
hood of catastrophe but cannot guarantee 100% safety.

Important Notice

Internet of Things (IoT)

• The IOT wireless communications category describes the Low Power Wide Area 

(LPWA).  This  technology  is  designed  to  provide  full-range  coverage  both  inside  and 
outside buildings, energy-saving and low-cost operation of individual devices. The 
LoRa network is available to use this standard.

LoRa network information

•  The network is bidirectional and its communication uses free frequency band.

•  865 - 867 MHz 

India

•  867 - 869 MHz  

Europe

•  902 - 928 MHz 

North America, Japan, Korea

•  The advantage of this network is the possibility of freely deploying individual stations 

in local locations, thus strengthening their signal. It can therefore be used effi

  ciently in 

company premises or, for example, in local parts of cities.

•  For more information on this technology, please visit www.lora-alliance.org.

Caution for proper operation:

•  Products are installed according to the wiring diagram given for each product.
•  For proper device functionality, it is necessary to have suffi

  cient coverage of the se-

lected network at the installation site.

•  At the same time, the device must be registered in the network. Successful device reg-

istration on a given network requires a charge for traffi

  c.

•  Each network off ers diff erent tariff  options - it always depends on the number of mes-

sages you want to send from your device. Information on these tariff s can be found in 
the current version of the ELKO EP pricelist.