IVEX Series Explosion Proof Camera Manual
Sealing fitting connection
•
When using the sealing fitting,
it is possible to use it normally
when the inside of the sealing fitting
is finished with a compound
as shown in the picture.
Loctite 263
•
In the case of sealing fitting, fasten the NPT ¾ nipple of
①
first, and then fasten the sealing fitting of
②
to the opposite side of the nipple.
•
Next, when the cable entry is completed, a compound (pipe sealant)
is injected to close the inside of the sealing fitting.
•
At this time, apply enough locking compound (Loctite 263)
to the fastening hole.
①
②
It is strongly recommended that all devices be carried out after final testing
prior to installation at the final installation site.
Ground installation method
•
M6 Lug
•
Material: copper, tin alloy
•
The product must be grounded with an external cable
(16AWG) with a 4mm² cross section.
•
Use the ground lug provided with the product and
M5*8 (wrench bolt) screws to fix the lug to be used for
power connection to the grounding hole with the L wrench
provided.
•
A separate press is required to press the lugs.
•
At this time, the presser is not provided separately.
How to Installation