background image

4

GB

!

 Before operating your new appliance please read

this instruction booklet carefully. It contains
important information concerning the safe installation
and operation of the appliance.

!

 Please keep these operating instructions for future

reference. Make sure that the instructions are kept
with the appliance if it is sold, given away or moved.

!

 The appliance must be installed by a qualified

professional according to the instructions provided.

!

 Any necessary adjustment or maintenance must be

performed after the cooker has been disconnected
from the electricity supply.
! We recommend cleaning the oven before using it
for the first time, following the instructions provided
in the "Care and maintenance" section.

Room ventilation

The appliance may only be installed in permanently-
ventilated rooms, according to current national
legislation. The room in which the appliance is
installed must be ventilated adequately so as to
provide as much air as is needed by the normal gas
combustion process (the flow of air must not be
lower than 2 m

3

/h per kW of installed power).

The air inlets, protected by grilles, should have a
duct with an inner cross section of at least 100 cm

2

and should be positioned so that they are not liable
to even partial obstruction (

see figure A).

These inlets should be enlarged by 100% - with a
minimum of 200 cm

2

 - whenever the surface of the

hob is not equipped with a flame failure safety
device. When the flow of air is provided in an
indirect manner from adjacent rooms (

see figure B),

provided that these are not communal parts of a
building, areas with increased fire hazards or
bedrooms, the inlets should be fitted with a
ventilation duct leading outside as described above.

A

B

!

 After prolonged use of the appliance, it is

advisable to open a window or increase the speed of
any fans used.

Disposing of combustion fumes

The disposal of combustion fumes should be
guaranteed using a hood connected to a safe and
efficient natural suction chimney, or using an electric
fan that begins to operate automatically every time
the appliance is switched on (

see figure).

!

 The liquefied petroleum gases are heavier than air

and collect by the floor, therefore all rooms
containing LPG cylinders must have openings
leading outside so that any leaked gas can escape
easily.
LPG cylinders, therefore, whether partially or
completely full, must not be installed or stored in
rooms or storage areas that are below ground level
(cellars, etc.). Only the
cylinder being used should be stored in the room;
this should also be kept well away from sources
of heat (ovens, chimneys, stoves) that may cause
the temperature of the cylinder to rise above 50°C.

Positioning and levelling

!

 It is possible to install the appliance alongside

cupboards whose height does not exceed that of the
hob surface.

!

 Make sure that the wall in contact with the back of

the appliance is made from a non-flammable, heat-
resistant material (T 90°C).

To install the appliance correctly:
• Place it in the kitchen, dining room or the bed-sit

(not in the bathroom).

• If the top of the hob is higher than the cupboards,

the appliance must be installed at least 200 mm
away from them.

• If the cooker is installed underneath a wall cabinet,

there must be a minimum distance of 420 mm
between this cabinet and the top of the hob.

This distance should be increased to 700 mm if

the wall cabinets are flammable (

see figure).

A

Fumes channelled through
a chimney or branched
flue system  reserved for
cooking appliances)

Installation

Adjacent room

Room requiring
ventilation

Ventilation opening for
comburent air

Increase in the gap between
the door and the flooring

Fumes channelled
straight outside

Содержание I5GG0G

Страница 1: ...n of the appliance Overall view 2 Description of the appliance Control Panel 3 Installation 4 Start up and use 8 Cooking modes 9 Precautions and tips 11 Care and maintenance 12 Assistance 12 1 2 3 14...

Страница 2: ...Containment surface for spills 4 Control panel 5 Sliding grill rack 6 DRIPPING pan 7 Adjustable foot 8 GUIDE RAILS for the sliding racks 9 position 5 10 position 4 11 position 3 12 position 2 13 posi...

Страница 3: ...appliance Control panel 1 GAS BURNER IGNITION button Only on certain models 2 TIMER knob Only on certain models 3 OVEN AND GRILL CONTROL knob 4 OVEN LIGHT ROTISSERIE button Only on certain models 5 H...

Страница 4: ...of the appliance it is advisable to open a window or increase the speed of any fans used Disposing of combustion fumes The disposal of combustion fumes should be guaranteed using a hood connected to...

Страница 5: ...ctrical socket must be easily accessible The cable must not be bent or compressed The cable must be checked regularly and replaced by authorised technicians only The manufacturer declines any liabilit...

Страница 6: ...eplace all the components by following the above instructions in reverse Adjusting the hob burners minimum setting 1 Turn the tap to the minimum position 2 Remove the knob and adjust the regulatory sc...

Страница 7: ...4 cm height 17 cm Power supply voltage and frequency see data plate Burners may be adapted for use with any type of gas shown on the data plate which is located inside the flap or after the oven compa...

Страница 8: ...fer to the diagrams contained in the Burner and nozzle specifications Using the oven The first time you use your appliance heat the empty oven with its door closed at its maximum temperature for at le...

Страница 9: ...grill leave the oven door ajar positioning the deflector D between the door and the control panel see figure in order to prevent the knobs from overheating Turnspit To operate the rotisserie see diag...

Страница 10: ...80 200 180 200 10 10 10 45 50 45 55 45 50 Pizza Napolitan 1 0 4 210 220 15 20 25 Cake Biscuits Tarts Savoury pie Raised Cakes 0 5 1 1 1 0 1 0 4 4 4 4 180 180 180 170 15 15 15 15 25 35 40 45 50 55 40 4...

Страница 11: ...and that the gas tap is closed when the appliance is not in use When unplugging the appliance always pull the plug from the mains socket do not pull on the cable Never perform any cleaning or mainten...

Страница 12: ...ss steel can be marked by hard water that has been left on the surface for a long time or by aggressive detergents containing phosphorus After cleaning rinse well and dry thoroughly Any remaining drop...

Страница 13: ...erving the environment Whenever possible avoid pre heating the oven and always try to fill it Open the oven door as little as possible because heat is lost every time it is opened To save a substantia...

Страница 14: ...14 UA i i i i i 2 3 100 2 A 100 200 2 B 50 C 90 C 200 esso 420 700 A A B...

Страница 15: ...15 UA 200 3 NFC 15 100 50 C HOOD 420 Min min 650 mm with hood min 700 mm without hood mm 600 Min mm 420 Min mm i i 8 13 50 C 1500...

Страница 16: ...16 UA A V 2 1 i 1 2 2 1 2 7 3 1 2 3 1 2 A 3 V 4 7 1 2 10 MA 3 4...

Страница 17: ...p c s 1 100 1 100 1 100 1 100 R 100 3 00 0 7 41 87 218 214 128 286 143 286 S 75 1 90 0 4 30 70 138 136 104 181 118 181 A 51 1 00 0 4 30 52 73 71 76 95 80 95 2 80 1 0 46 80 204 200 119 267 132 257 2 30...

Страница 18: ...18 UA 1 2 3 C 1 X 2 3 1 F 15 1 6 1 F i i R 24 26 S 16 20 A 10 14 X C...

Страница 19: ...19 UA 140 C MA 250 C F 4 5 1 6 1 D 1 1 2 4 3 1 2 S S D A S...

Страница 20: ...0 10 10 10 10 95 100 90 100 100 110 70 80 70 80 100 105 1 1 1 5 1 0 3 3 3 180 200 180 200 180 200 10 10 10 45 50 45 55 45 50 1 0 4 210 220 15 20 25 i 0 5 1 1 1 0 1 0 4 4 4 4 180 180 180 170 15 15 15 1...

Страница 21: ...21 UA i i i 1 2 1 i i 2002 96 CE RAEE i i...

Страница 22: ...22 UA i i 1 2 230 25 E 14 3 i S N...

Страница 23: ...40 40 40 1 2 3 40 4 5 6 7 8 9 10 23 UA...

Страница 24: ...24 UA 04 2014 195122644 00 XEROX FABRIANO Indesit Company S P A Viale Aristide Merloni 47 60044 Fabriano AN www indesit com...

Отзывы: