42
Line Power Module Installation
SmartNode
Description
SmartNode 1200
In the absence of an NT the PM-BRI-ext may be connected directly to the
BRI 0 port on the SmartNode. The terminals are connected to the BRI 1 port.
See Figure 9-3.
SmartNode 1400
The PM-BRI-ext is connected to the S-Bus via an S-Bus Multi-socket. See
Figure 9-4. This method can also be used on the SmartNode 1200.
9.5.3 SmartNode
1200
Warning:
Do not plug the Phantom Power supply directly into any other Port than BRI 0. Installing
it on the Ethernet Ports or Console Port could result in serious equipment damage.
Figure 9-3: SN1200 External 40V Power Supply
9.6 SmartNode
1400
Connect the PM-BRI-ext directly on one S-Bus on port BRI 0 or BRI. Use a commercially available S-
Bus 3-way multi-socket connector. The line power is fed through to the other BRI port. See Figure 9-4
for an example.
Hardware Installation Guide, Revision 3.11