29
PULSEMIG 300-T2
EN
Standard 4 times mode
O
N
Is
ta
rt
Dstart
G
as
P
re
-F
lo
w
T burn-back
I b
ur
n-
ba
ck
O
N
Gas post-Flow
O
FF
O
FF
In standard 4T, the time of the pre-gas and post-gas is managed by the trigger.
2 times pulse process
O
FF
Is
ta
rt
Dstart
I h
ot
s
ta
rt
T hotstart
T upslope
G
as
P
re
-F
lo
w
V
ite
ss
e
d'
ap
pr
oc
he
T downslope
I blackout
T burn-back
I b
ur
n-
ba
ck
O
N
Gas post-Flow
I
Soft-start
Pressing the trigger will initiate pre-gas. When the wire touches the workpiece a pulse boots the arc. The
machine initiates the Hot-start, upslope and then the welding process begins. When you release the trigger
the downslope will start until the Iblackout is reached. At this point a peak of current will cut the wire and
follows the post-gas. As in standard mode, you can carry on the welding during the post gas. Wait until the
end of the post gas to modify the parameters.