28
PULSEMIG 300-T2
EN
Save:
To save a welding program you need to enter a number and a name. (7
letters) In the event of use with several torches, select the torch used before
getting back the memory.
SD card with version V1005 allows using synergic welding for the material and diameters in the chart below:
List of synergic modes (V1012)
Std
Ø0.6
Ø0.8
Ø1
Ø1.2
Puls
Ø0.6
Ø0.8
Ø1
Ø1.2
Fe Arg CO2 18%
X
X
X
X
X
Al Mg 5 Arg 100%
X
X
X
X
X
X
Al Si 12 Arg 100%
X (P.P)
X
X
X (P.P)
X
X
Al Si 5 Arg 100%
X (P.P)
X
X
X (P.P)
X
X
Cr Ni 308 Arg 100%
X
X
X
X
Cr Ni 316 Arg 100%
X
X
X
X
Cu Si 3 Arg 100%
X
X
X
X
Cu Al 8 Arg 100%
X
X
X
X
Fe CO2 100%
X
X
Information panel
It contains the indices and sub-indices of the circuits and
the software version (HMI, power, SD card ...)
Example:
WELDING STAGES
Standard 2 times mode
O
FF
Is
ta
rt
Dstart
Ga
s
Pr
e-
Fl
ow
T burn-back
I b
ur
n-
ba
ck
O
N
Gas post-Flow
Pressing the trigger will start pre-gas. When the wire touches the workpiece a pulse boots the arc and the the
welding process starts. When you stop pressing the trigger, the wire feeder stops working and a current pulse will
cut the wire, and will be followed by post-gas. As long as the post gas is not finished, you can pull the trigger to
carry on the welding (delay in manual). To modify the parameters you have to wait until the end of the post gas.