![IMS PULSEMIG 300-T2 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/ims/pulsemig-300-t2/pulsemig-300-t2_manual_2049892026.webp)
26
PULSEMIG 300-T2
EN
Pulse in Pulse (PIP) or double
pulse
Same settings in Pulse mode (PLS). See previous paragraph for more details. There are extra phases
specific to the PIP (Pulse In Pulse) mode :
I cold :
current proportion for the background current phase.
Delta U Cold :
acts on the arc length during the cold phase.
THigh :
current proportion for the welding current (main/hot phase).
TPulse :
phase duration.
Can also adjust the pulse frequency on the welding curve (using the control panel).
STD mode
There are phases of: pre gas, creep speed, Hot start, Crater filler and post gas.
BurnBack High :
can remove the wire cut pulse, useful for thin sheets.
EASY INTERFACE
As with the PRO interface the top part of the screen allows you to select
the wire diameter, gas-metal combination, welding process (standard,
pulse, manual) and trigger mode (2T, 4T).
The icon allows you to enter the secondary menu of EASY interface.
To enter the welding process menu, you must access PRO interface and
click on the
icon.
With the EASY interface, the operator will have access to two parameters:
Metal thickness and arc length
Spot/Delay mode
The Spot mode allows the user to score the metal by adjusting the length of
the point. The Delay mode (or spot and delay) allows the operator to adjust
the welding time of the point and the delay between two points for chain
stitch welding (Available only with EASY interface).