EN
45
Operating manual
ARCPULL 350
Translation of the original
instructions
Unscrew the two front-panel screws and release the
cover slightly towards the front of the gun.
Slightly loosen the two rod-clamping screws.
If changing the rods, remove them by pulling on
them, then replace them with new ones.
Adjust the length of the gun’s earthing rods accor-
ding to the type of welding consumable being used
(suitable for the distance between the end of the
earthing rods and the edge of the flanges).
Consumables
L (mm)
Gun ring support (059610)
120 mm
ARCPULL rivet kit 1 350 - 24 kN
(064584)
55 mm
ARCPULL rivet kit 3 350 - 50 kN
(073388)
75 mm
Stud support kit (M4 - M8) (068339)
120 mm
Ceramic adaptor (Ø 6 and Ø 8)
(075979)
120 mm
Difficult-access stud support box (M4 -
M8) (070813)
75 mm
L
Slightly loosen the two rod-clamping screws.
Replace the cover on the front of the gun and
tighten the two retaining screws.
6.2. ADJUSTING A STUD SUPPORT/INSULATING NAIL SUPPORT
Note 1: The rivet-extraction stud support’s settings are different. This is detailed in the following sections: 6.4 and 6.5.
Note 2: When installing insulation nails, no adjustment is necessary. Insert the insulation nail up to the nail holder limit
stop.