background image

IMPEY SHOWERS LTD

Conquest Business Park, Ilton, Somerset, TA19 9EA

[email protected]

Tel: 01460 256080 • Fax: 01460 259800

CARE AND MAINTENANCE

IMPORTANT: 

When silicone sealant is used you must not use or work on 

the panel/s for 24 hours after installation.

DO NOT 

use bleach, scouring powders, solvents or other aggressive 

cleaning agents. 
To clean use warm soapy water and a clean cloth and rinse off.
Periodically check all fixings and tighten if necessary.

Please note: There has been a glass coating applied to this product, 
use a squeegee to remove water and debris.

RECYCLING 

Packaging:-

 The cardboard and polythene parts of this packaging  

can be recycled.

End of life:- 

This product contains materials such as aluminium and  

glass which can be recycled.

Please contact your local authority to find your nearest recycling centre.

TECHNICAL HELPLINE: 01460 258682

PAGE 20

10

Seal along the bottom of both sides of the glass, outside of the bottom of the wall channel, 
50mm up the wall channel and the joint between the wall channel and panel.

Optional foot

 - apply silicone sealant along the bottom of the 

optional foot

, as shown.

Outside of foot

Inside of foot

Carefully push the panel back into the wall 
channel (

1

). Slide the panel down the wall 

channel and into the foot (

2

).

Reattach the tie bar.

Option B -

 

continued

1

2

2

1

Inside 

From inside, if required adjust the height of the foot (

1

) so that the panel 

is vertical. slide the spacer plate (PN80583) down between  
the bracket and glass panel.
Tighten the grub screw (

2

) onto the panel.

 

Push fit the screw cover 

caps.

3mm

PN80583

Содержание AQUA SCREEN PURE

Страница 1: ...uture reference Incorrect fitting will invalidate the guarantee SAFETY Handle glass with care Although the glass is very tough sharp impacts can damage both the glass and metal frame Do not remove the...

Страница 2: ...outside of the panel Satin glass patterns MUST be installed to the outside of the panel Note The Glass Guard coating is on the opposite side to the label or satin glass patterns 5 4 If using the thre...

Страница 3: ...6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same width as the panel Measure the height of the threshold strip X and remove the same amount off each...

Страница 4: ...ie bar g From inside tighten the grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push f...

Страница 5: ...he correct way around into the wall channel Note Wetting the edge of the panel with water will help the panel insert If not using the threshold strips proceed straight to step 7 4 If using the thresho...

Страница 6: ...position of the angled tie bar bracket onto the wall Approx 250mm PN80499 PN80499 3mm 2mm 2mm 6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same widt...

Страница 7: ...he grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Tighten the large screws on both of...

Страница 8: ...PN10754 Wall channel PN10754 1 Plan position of panels The size of the opening will depend on the tray if used or the site conditions To fit the DOUBLE PANEL WITH ANGLED TIE BARS option follow the sam...

Страница 9: ...ss Guard coating is on the opposite side to the label or satin glass patterns Tie bar PN10786 Wall channel PN10754 Corner joint PN11011 5 4 If using the threshold strip s there are 2 types available A...

Страница 10: ...r joint short side as shown onto the main panel b Carefully measure and trim your chosen threshold strip down to the width of the panel minus the corner joint c Measure the height of the threshold str...

Страница 11: ...Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push fit the top cap onto the top of the wall channel 32 mm a 1 2...

Страница 12: ...oot so it is flush with the underside Place the inner foot into the foot Position the assembled foot under the return panel flush with the edge d Ensure the return panel is vertical and if required ad...

Страница 13: ...ling foot to floor Use the allen key to remove the pin from the inner foot Apply silicone sealant to the underside of the inner foot Position the assembled foot in the marked position b 15 Apply silic...

Страница 14: ...e wall b If required trim the tie bars to length X 50mm c Assemble the tie bars slide on the top panel brackets and tie bar brackets Lightly tighten the fitted grub screws X Wall Opening X 50mm a b c...

Страница 15: ...e tie bars 2 Push fit the screw cover caps 32 mm a c d b 2mm 1 2 g Inside 3mm 5 a Carefully place the tie bar assemblies onto the glass approximately 100mm from the edges depending on your installatio...

Страница 16: ...el c Use the 3mm allen key to wind up the pin on each inner foot so they are flush with the underside Place the inner feet into the feet Position the assembled feet under the return panels flush with...

Страница 17: ...hole Position the assembled feet in the marked position Option b Sealing feet to floor Use the allen key to remove the pins from the inner feet Apply silicone sealant to the underside of the inner fee...

Страница 18: ...nel with water will help the panel insert 6 mm a b d 32 mm 1180mm max c PN80499 PN80499 PN80506 5 4 Ensure that the open end of the panel is vertical and the panel is parallel with the opposite wall W...

Страница 19: ...ten the large screws on both tie bar brackets 7 Push fit the top cap onto the top of the wall channel 32 mm a 1 2 c d g Inside b 3mm 2mm 8 Foot Options Option A Without foot follow step 10 Option B Wi...

Страница 20: ...contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre TECHNICAL HELPLINE 01460 258682 PAGE 20 10 Seal along th...

Отзывы: