PAGE 6
PN80499
PN80506
8
7
Ensure that the open end of the panel is vertical
and the panel is parallel with the opposite wall.
Wall
Opening
=
=
a:
Loosen the large screw on both tie bar brackets.
b:
Slide a tie bar bracket onto both ends of the tie bar and position the top panel bracket onto one of the tie bar brackets. Lightly tighten the fitted grub screws.
c:
Carefully place the tie bar assembly onto the glass, approximately 250mm from the edge (depending on your installation), angle the tie bar brackets as required.
Important note:
The tie bar will be most effective when at a 45 degree angle to the panel and wall.
d:
If required, trim the tie bar to length
e
&
f:
Ensure the panel is vertical and the tie bar is level, mark the position of the angled tie bar bracket onto the wall.
Approx.
250mm
PN80499
PN80499
3mm
2mm
2mm
6
Remove the panel from the wall channel.
Carefully
trim your chosen threshold strip down to the same width as the panel.
Measure the height of the threshold strip
‘X’
and remove the same amount off each ‘seal’.
A:
Aluminium threshold strip
- Position the strip inside the wall channel. Run a bead of silicone sealant down the length of the threshold strip.
Angle the panel and carefully push (the correct way around) into the wall channel and threshold strip. Wipe off any excess silicone.
B:
Plastic threshold strip
- Position the strip onto the bottom of the panel, flush with the front edge (
1
). Carefully push the panel (the correct way
around) into the wall channel (
2
) and ensure the strip makes full contact with the floor.
2
1
A
B
Option 2 -
Fitting threshold strips inside the wall channel
Sealant
A
X
= Height of
threshold strip
a
b
c
e
f
d