background image

PAGE 16

9

Option B -

 

Return panels with threshold strips

a

b

a: 

Temporarily,

 

position the return panels into the ‘long side

*

’ of the corner joints. 

(Ensure ‘Glass Guard H2o’ label is to the outside of the panel.) 

b: 

Position the ‘short side’ of the corner joints onto the main panel.

c: 

Carefully

 measure the length of return panel protruding out of the corner  

joints = 

‘X’.

d: 

Carefully trim your chosen threshold strips to length 

‘X’

.

Remove the corner joints and return panels.

X

c

d

MAIN 

PANEL 

(outside)

e:

 Apply silicone sealant down the inside of the ‘long and short sides’ of the corner joints.

f:

 Push fit the corner joint caps on to the corner joints.

g:

 

Carefully

 push the ‘short side’ of the corner joints fully onto the main panel. 

e

f

g

*

X

RETURN 

PANEL

(outside) 

RETURN 

PANEL

(outside) 

RETURN 

PANEL

(outside) 

10

Option C -

 

Return panels with threshold strips and feet

     &     

Option D -

 

Return panels with feet only

c

a: 

Temporarily,

 

position the return panels into the ‘long side

*

’ 

of the corner joints. (Ensure ‘Glass Guard H2o’ label is to the 
outside of the panel.)

b: 

Position the ‘short leg’ of the corner joints onto the main 

panel.

c:

 Use the 3mm allen key to wind-up the pin on each inner foot

*

 

so they are

 

flush with the underside. Place the inner 

feet into the feet.

 

Position the assembled feet under the return panels, flush with the edge. 

d: 

Ensure the return panels are vertical and if required adjust the feet to level the panels. Mark the position of the feet 

onto the floor (all the way around). 

Carefully

 measure the return panels between the corner joint and foot = 

‘X’.

e: 

Carefully trim your chosen threshold strips to length 

‘X’

.

Remove the corner joints, return panels and feet.

*

a

b

X

d

X

e

*

RETURN 

PANEL

(outside) 

RETURN 

PANEL

(outside) 

3mm

Option B -

 

continued

A:

 

Aluminium threshold strip

 - Position the strips up against the corner joints. 

Run a bead of silicone sealant down the length of the threshold strips. Carefully 
push the return panels (the correct way around) into the corner joints (

1

). Slide the 

return panels down the corner joints and into the threshold strips (

2

). Wipe off any 

excess silicone.

B:

 

Plastic threshold strip

 - Position the strips onto the bottom of the return panels, 

flush with the front (

1

). Carefully push the return panels (the correct way around) into 

the corner joints (

2

) and ensure the strips makes full contact with the floor.  

Now proceed straight to step 11 to seal the enclosure.

1

2

2

1

A

B

Sealant

A

Содержание AQUA SCREEN PURE

Страница 1: ...uture reference Incorrect fitting will invalidate the guarantee SAFETY Handle glass with care Although the glass is very tough sharp impacts can damage both the glass and metal frame Do not remove the...

Страница 2: ...outside of the panel Satin glass patterns MUST be installed to the outside of the panel Note The Glass Guard coating is on the opposite side to the label or satin glass patterns 5 4 If using the thre...

Страница 3: ...6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same width as the panel Measure the height of the threshold strip X and remove the same amount off each...

Страница 4: ...ie bar g From inside tighten the grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push f...

Страница 5: ...he correct way around into the wall channel Note Wetting the edge of the panel with water will help the panel insert If not using the threshold strips proceed straight to step 7 4 If using the thresho...

Страница 6: ...position of the angled tie bar bracket onto the wall Approx 250mm PN80499 PN80499 3mm 2mm 2mm 6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same widt...

Страница 7: ...he grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Tighten the large screws on both of...

Страница 8: ...PN10754 Wall channel PN10754 1 Plan position of panels The size of the opening will depend on the tray if used or the site conditions To fit the DOUBLE PANEL WITH ANGLED TIE BARS option follow the sam...

Страница 9: ...ss Guard coating is on the opposite side to the label or satin glass patterns Tie bar PN10786 Wall channel PN10754 Corner joint PN11011 5 4 If using the threshold strip s there are 2 types available A...

Страница 10: ...r joint short side as shown onto the main panel b Carefully measure and trim your chosen threshold strip down to the width of the panel minus the corner joint c Measure the height of the threshold str...

Страница 11: ...Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push fit the top cap onto the top of the wall channel 32 mm a 1 2...

Страница 12: ...oot so it is flush with the underside Place the inner foot into the foot Position the assembled foot under the return panel flush with the edge d Ensure the return panel is vertical and if required ad...

Страница 13: ...ling foot to floor Use the allen key to remove the pin from the inner foot Apply silicone sealant to the underside of the inner foot Position the assembled foot in the marked position b 15 Apply silic...

Страница 14: ...e wall b If required trim the tie bars to length X 50mm c Assemble the tie bars slide on the top panel brackets and tie bar brackets Lightly tighten the fitted grub screws X Wall Opening X 50mm a b c...

Страница 15: ...e tie bars 2 Push fit the screw cover caps 32 mm a c d b 2mm 1 2 g Inside 3mm 5 a Carefully place the tie bar assemblies onto the glass approximately 100mm from the edges depending on your installatio...

Страница 16: ...el c Use the 3mm allen key to wind up the pin on each inner foot so they are flush with the underside Place the inner feet into the feet Position the assembled feet under the return panels flush with...

Страница 17: ...hole Position the assembled feet in the marked position Option b Sealing feet to floor Use the allen key to remove the pins from the inner feet Apply silicone sealant to the underside of the inner fee...

Страница 18: ...nel with water will help the panel insert 6 mm a b d 32 mm 1180mm max c PN80499 PN80499 PN80506 5 4 Ensure that the open end of the panel is vertical and the panel is parallel with the opposite wall W...

Страница 19: ...ten the large screws on both tie bar brackets 7 Push fit the top cap onto the top of the wall channel 32 mm a 1 2 c d g Inside b 3mm 2mm 8 Foot Options Option A Without foot follow step 10 Option B Wi...

Страница 20: ...contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre TECHNICAL HELPLINE 01460 258682 PAGE 20 10 Seal along th...