Getting Started
15
Chapter 2
Getting Started
2.1 Introduction
In this chapter, you are shown how to install your RS-0800-LVD enclosure and plug-in modules into an
industry standard 19 inch rack cabinet.
Caution
When connecting up the RS-0800-LVD subsystem, use the power cords supplied or ones which match
the specification quoted in section
1.5.4
.
2.2 Planning Your Installation
Before you begin installation you should become familiar with the configuration requirements of your RS-
0800-LVD system, detailed in
Table 2–1
. The correct positions of each of the optional plug-in modules
are shown in
Figure 2–1
. Please refer to Section
2.6
for details of Ultra-320 SCSI configurations and
installation.
Table 2–1
RS-0800-LVD Configuration
Module Location
Drive Bays
ALL drive bays must be filled with either a Drive Carrier module or a dummy
carrier module, no bays should be left completely empty.
Power Supply
Modules
• One Power Supply module provides power for a full configuration of 8
drives, 2 I/O modules and 2 Cooling modules. Install the module in bay 1
and a Blank Power Supply module in Bay 3
• Two Power Supply modules: provide redundancy with power to the drives
maintained while a faulty module is replaced. Install the modules in bays
1 and 3
SCSI I/O Modules
Two modules must be fitted in the top right and left hand rear bays.
Содержание RS-0800-LVD
Страница 1: ...RS 0800 LVD Installation and User Guide Part No 34981 02A Issue 2 0 January 15 2004...
Страница 6: ...vi RS 0800 LVD User Guide...
Страница 19: ...Introduction 7 Figure 1 10Ultra 320 SCSI IO Module Figure 1 11 Ultra 320 SCSI Loopback Module...
Страница 26: ...RS 0800 LVD User Guide 14...
Страница 42: ...RS 0800 LVD User Guide 30...
Страница 58: ...RS 0800 LVD User Guide 46...