background image

Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy

Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it  E-Mail: [email protected]

9

iMode Digital Loudspeaker Processor

iP24

COMPUTER, iPAD® AND iPHONE® CONNECTION

The  connection  to  the 

  must  be  made  through 

computer

an 

ethernet 

CAT 

network, using standard 

5 network cables.

The connection to the iPad

 iPhone

 

®,

® or computer with wifi

requires the construction of a wireless network. Therefore it 
will be necessary to use a wireless router (not included), that 
can  also  work  as  a  DHCP  server  (see  the  “Network  setup” 
paragraph for more information).
The ethernet cable from the computer or the access point has 
to be plugged into the connector called 

 of the iP24. 

“PORT 1”

The other iP24 can be connected directly to the access point 
(using an other available LAN port) or can be daisy chained from 
the first iP24. In this case a network cable has to be plugged 
from 

2  of the first device to the 

 of the next 

“PORT  ”

“PORT 1”

iP24.

SOFTWARE

In case of use with a personal computer, no special software is 
required,  but  just  a  web  browser  that  supports  Java® 
applications. In order to communicate with a single iP24, start 
the  web  browser  and  write  the  device’s  IP  address  in  the 
address  bar.  The  Java  application  will    start  automatically. 
Using  this  application  it  will  be  possible  to  control  all  the 
parameters of the single device, but not the groups.
The application called “iP24  for iPad® is available on the App 

Store.  Through  this  application  is  possible  to  monitor  and 
control each single device and groups of iP24. It is possible to 
save and share, via e-mail, all the parameters of all the devices 
in the project, as well as to work in offline mode.

NETWORK SETUP

Outline iP24 uses the TCP and UDP, according to standard RFC 
768.
All  the  devices  (processors,  computer,  iPad®  and  router) 
connected  to  the  same  local  network  communicate  via  IP 
addresses.  The  basic  rules  of  this  addressing  mode  are 
presented here:

Ÿ

each device must have an assigned IP address;

 

Ÿ

  the IP addresses must be unique (no duplicates);

Ÿ

  all the IP addresses have to belong to the same subnet.

I.e if the loudspeaker has the following network settings:
 

 

IP

:  

 192.168.1.34

 address

 

 

SUBNET MASK: 

255.255.255.0

In  order  to  have  the  communication  with  the  computer,  the 
iPad® or the router, the latter must have a different IP address 
belonging  to  the  same  subnet.  In  this  case,  one  possible 
network address for computer is:
 

 

IP

:  

 192.168.1.10

 address

 

 

SUBNET MASK: 

255.255.255.0

The  IP  addresses  can  be  assigned  manually  or  automatically 
(DHCP).The  iP24  are  supplied,  as  standard,  with  the  DHCP 
option enabled.

DHCP  means  "Dynamic  Host  Configuration  Protocol".  If  this 
option is enabled, the devices are waiting for a valid IP address 
from  a  DHCP  server  (usually  implemented  in  any  wireless 
router) for about one minute. It is strongly suggested to switch 
on the router before any device.

COLLEGAMENTO CON IL COMPUTER O iPAD®/iPHONE®

Il  collegamento  con  il  computer  deve  essere  effettuato 
mediante la rete 

 utilizzando cavi di rete CAT 5.

ethernet,

 

Il  collegamento  ad  un  iPad®,  iPhone®  o  computer  con  wifi 
avviene tramite la costruzione di una rete wireless. Sarà quindi 
indispensabile utilizzare un router wireless (non fornito), che 
sia  in  grado  di  funzionare  anche  come  DHCP  server  (vedi  il 
paragrafo “Configurazione della rete”).
Il  cavo  proveniente  dal  computer  o  dall’access  point  deve 
essere  collegato  al  connettore  ethernet  chiamato  “PORT  1” 
del iP24.  I  successivi  iP24  possono  essere  collegati 

l’

direttamente all’access point (utilizzando una delle porte LAN 
disponibili) oppure in successione al primo iP24. In questo caso 
collegare un cavo dal connettore “PORT 2” del primo iP24 al 
connettore “PORT 1” del successivo.

SOFTWARE

Nel  caso  di  utilizzo  con  personal  computer  non  è  necessario 
installare alcun software. E’ sufficiente utilizzare un comune 
web  browser  che  supporti  le  applicazioni  Java®.  Per 
comunicare con 

 singolo 

 aprire il web browser e digitare 

un

iP24

l’inidirizzo  IP 

  nella  barra  degli  indirizzi. 

del  dispositivo

Comparirà  automaticamente  l’applicazione  Java,  tramite  la 
quale  è  possibile  controllare  tutti  i  parametri  inerenti  alla 
singola macchina, ma non ai gruppi.
Sull’Apple Store è disponibile l’applicazione “iP24" per iPad®. 
Questa consente il monitoraggio, il controllo contemporaneo e 
la  gestione  a  gruppi  di  più  iP24.  È  possibile  memorizzare  e 
condividere, tramite e-mail, i parametri di più macchine, così 
come realizzare progetti off-line.

CONFIGURAZIONE DELLA RETE

I processori iP24 utilizzano un protocollo di rete di tipo TCP e 

 

UDP, conforme allo standard RFC 768.
Tutti  i  dispositivi  (processori,  computer,  iPad®  e  router) 
connessi  in  una  rete  locale  comunicano  tramite  indirizzi  IP. 
Perchè tutto funzioni é necessario che:

Ÿ

  a ciascun dispositivo sia assegnato un indirizzo IP;

Ÿ

  non esistano indirizzi IP duplicati;

Ÿ

  tutti gli indirizzi IP appartengano alla stessa sottorete.

Ad  esempio,  se  il  dispositivo  ha  le  seguenti  impostazioni  di 
rete:
 

 

Indirizzo IP: 

  192.168.1.34

 

 

SUBNET MASK: 

255.255.255.0

Per far sì che ci sia comunicazione con il computer

o il 

, l’iPad® 

router,  è  necessario  che  quest’ultimo  abbia  un  indirizzo  IP 
diverso,  ma  che  appartenga  alla  stessa  sottorete.  In  base 
all’esempio proposto una possibile configurazione di rete per il 
computer é la seguente:
 

 

Indirizzo IP: 

  192.168.1.10

 

 

SUBNET MASK: 

255.255.255.0

Questi  indirizzi  IP  possono  essere  assegnati  manualmente  o 
automaticamente (DHCP). I processori iP24 vengono forniti, di 
fabbrica, con l'opzione DHCP abilitata.

DHCP  significa  "Dynamic  Host  Configuration  Protocol".  Con 
questa opzione abilitata i dispositivi attendono l'assegnazione 
di  un  indirizzo  IP  valido  da  un  server  DHCP  (di  solito 
implementato in 

router wireless) per circa un minuto.

ogni 

 È 

consigliato accendere il router prima di ogni dispositivo.

COMUNICAZIONE CON IL DISPOSITIVO / COMMUNICATION WITH THE DEVICE

Содержание IP24

Страница 1: ...DeliveringtheTrueAudioExperience MANUALE ISTRUZIONI OPERATING MANUAL ...

Страница 2: ...ot expose the unit to rain and don t use it in locations with a high humidity level Ensure that no liquids or solid objects accidentally enter the unit should this occur stop using the unit and contact OUTLINE or specialist staff When connecting the unit ALWAYS check ground connection as required by technical and safety norms If the original cable is worn or damaged it must be replaced with anothe...

Страница 3: ...cchio ha spinto Outline ad una scelta minimalista per quanto concerne l interfaccia hardware Outline iP24 è infatti completamente controllabile da remoto mediante utilizzo di un protocollo Ethernet standard tramite web browser che supporti la tecnologia Java da computer o tramite dispositiviApple iOS e OSX Thank you for choosing Outline iP24 for the management of your loudspeaker system We suggest...

Страница 4: ...ng Rosso se l apparecchio è nello stato di mute impostabile da remoto o se il limiter è inserito indica che il circuito di limitazione sta intervenendo decisamente se il limiter non è inserito indica che il segnale è troppo elevato e sta clippando 1 STATUS this LED indicates that the device is working properly During the startup this LED remains red in order to indicate that the various checks are...

Страница 5: ... digitali secondo il protocollo AES EBU 6 AES EBU IN 1 2 connettori di tipo XLR per il collegamento degli ingressi digitali secondo il protocollo AES EBU 7 I O PORT connettore di tipo DB9 per utilizzo tipo generico programmabile da remoto 8 RS 485 connettore RJ45 per la comunicazione seriale RS 485 con altre apparecchiature ad esempio amplificatori Outline serie T Funzione non ancora disponibile 1...

Страница 6: ...visare il rivenditore Si consiglia di conservare l imballo da utilizzare in caso di trasporto dell unità in un secondo momento L unità Outline iP24 viene fornita con i seguenti accessori N 1 cavo di alimentazione Certificato di garanzia Questo manuale After unpacking the unit check very carefully for any damage If any damage is found please notify your dealer It is advisable to keep the packaging ...

Страница 7: ...ate elettronicamente Il collegamento avviene tramite connettori XLR INGRESSIANALOGICI Gli ingressi hanno un impedenza nominale di k 100 Ω Per i segnali non bilanciati utilizzare i pin HOT segnale in fase e GND massa ed consigliabile collegare a massa il pin COLD è segnale invertito di fase per ridurre al minimo il rumore MOUNTING The iP 24 has been designed for 19 standard rack mounting and occupi...

Страница 8: ...e provided and switch on the unit with the dedicated power button The unit will automatically turn on the STATUS LED will be red during the start up phase during this phase the unit will run also a LED check After this phase the STATUS LED will turn green or magenta depending on the input selected and the unit will be ready to be used CARATTERISTICHE FEATURES m Ingressi ed uscite analogiche e digi...

Страница 9: ... is strongly suggested to switch on the router before any device COLLEGAMENTO CON ILCOMPUTER O iPAD iPHONE Il collegamento con il computer deve essere effettuato mediante la rete utilizzando cavi di rete CAT 5 ethernet Il collegamento ad un iPad iPhone o computer con wifi avviene tramite la costruzione di una rete wireless Sarà quindi indispensabile utilizzare un router wireless non fornito che si...

Страница 10: ...attive altri network come in fiere grandi strutture o luoghi affollati usare reti wireless a 5 GHz non supportato da iPhone Per avere un controllo migliore sulle prestazioni della rete senza fili molti analizzatori wifi per computer tablet e telefoni sono disponibili sul web TROUBLESHOOTING If the DHCP is not available or if you do not know the IP address manually assigned to the iP24 unit you can...

Страница 11: ... 22 kHz Crosstalk Inputs 108 dB 20 Hz 20 kHz MaxInputLevel Crosstalk Outputs 93 dB 20 Hz 20 kHz MaxInputLevel Crosstalk 93 dB 20 Hz 20 kHz MaxInputLevel SEZIONEANALOGICA Numero di ingressi analogici Due ingressi analogici bilanciati elettronicamente Impedenza di ingresso analogica bilanciato 100 Ω k Numero di uscite analogiche Quattro uscite analogiche bilanciate elettronicamente Impedenza di usci...

Страница 12: ...or 1 x DB9 connectorwith two inputs and two free contact outputs Power supply connector 3 pin IEC connector SEZIONE DIGITALE Numero di ingressi digitali Due ingressi digitaliAES EBU un connettore due canali Number of digital outputs Quattro uscite digitaliAES EBU due connettori quattro canali Frequenze di campionamento supportate in ingresso 44 1 kHz 48 kHz 96 kHz 192 kHz THD N 140 dB 96 kHz 139 d...

Страница 13: ...WER SUPPLY Power requirements 90 V 50 60 Hz 264 AC Power consumption 20 W PHISICAL Dimensions 1U standard EIA Height 44 mm 1 75 Width 483 mm 19 Depth mm 175 6 9 Weight Kg net 2 6 SEGNALAZIONI Ingresso analogico 20 dBu di sensibilità Verde 46 dBu 11 dBu Giallo 11 dBu 20 dBu Rosso 20 dBu clip Uscita analogica limiter escluso Verde 46 dBu 11 dBu Giallo 11 dBu 20 dBu Rosso 20dBu clip Uscita analogica ...

Страница 14: ...nterno del processore The generic input output port on a DB9 connector gives you the possibility to interface the processor with an external control system i e a fire alarm or an external push button controller to change the levels The functions and the response of the device to an input are remotely programmable The settings are including muting of all the channels or of each single channel lower...

Страница 15: ...Outline s r l Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 30 3581341 Fax 39 30 3580431 Web Site www outline it E Mail info outline it 15 iMode Digital Loudspeaker Processor iP24 NOTE NOTES ...

Страница 16: ...ine potrà lievemente differire dalla sua descrizione qui pubblicata ma comunque uguaglierà o supererà le caratteristiche qui specificate Outline 2015 Manuale d istruzioni codice Z OMIP24V2 0 Versione 150730 Stampato in Italia Outline carries out on going research for product improvement New materials manufacturing methods and design upgrades are introduced to existing products without prior notice...

Отзывы: