43
3.26 TECHNICAL PARAMETERS FOR COMBINATION BOILERS
(
IN COMPLIANCE WITH REGULATION 813/2013
)
.
Efficiencies in the following tables refer to the gross calorific value.
Model/s:
Victrix Maior 28 TT 1 ErP
Condensing Boilers:
SI
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
SI
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
24
kW
Seasonal energy efficiency of central
heating
η
s
93
%
For central heating only and mixed boilers: useful heat output
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
24.0
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
87.6
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
8.1
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.6
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.018
kW
Heat loss in standby
P
stby
0.045
kW
At partial load
el
min
0.013
kW
Ignition burner energy consumption
P
ign
0.000
kW
In standby mode
P
SB
0.005
kW
Emissions of nitrogen oxides
NO
X
23
mg /
kWh
For mixed central heating appliances
Stated load profile
XL
Domestic hot water production efficiency
η
WH
85
%
Daily electrical power consumption
Q
elec
0.225
kWh
Daily gas consumption
Q
fuel
22.875
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera-
ture.
Model/s:
Victrix Maior 35 TT 1 ErP
Condensing Boilers:
SI
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
SI
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
34
kW
Seasonal energy efficiency of central
heating
η
s
93
%
For central heating only and mixed boilers: useful heat output
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
34.2
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
88.2
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
11.4
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.7
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.020
kW
Heat loss in standby
P
stby
0.051
kW
At partial load
el
min
0.012
kW
Ignition burner energy consumption
P
ign
0.000
kW
In standby mode
P
SB
0.004
kW
Emissions of nitrogen oxides
NO
X
24
mg /
kWh
For mixed central heating appliances
Stated load profile
XXL
Domestic hot water production efficiency
η
WH
85
%
Daily electrical power consumption
Q
elec
0.222
kWh
Daily gas consumption
Q
fuel
28.449
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tem-
perature.