2.4  USING THE BOILER.

Before ignition make sure the heating system 

is filled with water and that the manometer (7) 

indicates a pressure of 1 

÷

 1.2 bar.

- Open the gas cock upstream from the boiler.
- Press the button (6) until the display switches 

on. The boiler now returns to the state prior to 

switch-off.

-  If the boiler is in stand-by, press the button (6) 

again to activate it. If this is not the case, go to 

the next point.

- Then press the button (3) in sequence and set 

the boiler in the summer (

) or winter (

position.

 

Summer 

(

)

:

 in this mode the boiler only 

works to produce DHW; the temperature is set 

via the selector (1) and the relative temperature 

is shown on the display via the indicator (14).

 Winter 

(

)

:

 in this mode the boiler works 

both for producing domestic hot water and for 

central heating. The temperature of the DHW is 

always regulated via the selector (1), the heating 

temperature is regulated via selector (4) and the 

relative temperature is shown on the display via 

the indicator (14).

From this moment the boiler functions automati-

cally. With no demand for heat (central heating 

or domestic hot water production) the boiler 

goes to “standby” function, equivalent to the 

boiler being powered without presence of flame. 

Each time the burner ignites, the relative flame 

present symbol is displayed (10) with relative 

output scale.

 

Operation with Comando Amico Remoto

V2

 

(CAR

V2

) (Optional)

. If the CAR

V2

 is connected, 

the (

) symbol will appear on the display. 

The boiler regulation parameters can be set via 

the CAR

V2

 control panel and the reset button 

(2) remains active on the boiler control panel, 

along with the switch-off button (6) (“off ” 

mode only) and the display where the function-

ing state is shown.

  

Caution:

 if the boiler is switched “off” the 

CAR

V2

 will display the connection error symbol 

“ERR

>

CM”, the CAR

V2

 is however powered 

constantly so as not to lose the stored programs.

 

Boost Function.

 Pressing the “Info” and 

“Reset” buttons at the same time activates 

the “Boost” function indicated by the relative 

icon on the display. When the boiler is active 

it is maintained at a sufficient temperature to 

ensure the instantaneous delivery of hot water. 

To maintain the temperature the boiler may be 

switched on even without requests for domestic 

hot water or central heating; this type of op-

eration is indicated by the “BOOST” message 

flashing.

 

Solar operating mode (

).

 This function 

is always active and combined with the “Solar 

ignition delay” with time set above 0 seconds 

it manages the ignition of the boiler according 

to the domestic hot water inlet temperature.

  During a withdrawal, if the inlet water is hot 

enough or if there is “Solar ignition delay” time, 

the boiler does not switch on, the D.H.W. with-
drawal symbol (

) appears on the display 

along with the flashing solar function symbol 
(

).

  When the water supplied by the solar system is 

at a temperature lower than what is set, and / or 

if the “Solar ignition delay” time has elapsed, 

the boiler switches on. At this point, the solar 

function symbol will go off.

 

Operation with optional external probe 

(

)

.

 In the case of a system with optional 

external probe, the boiler flow temperature 

for room central heating is managed by the 

external probe depending on the external 

temperature measured (Par. 1.9). The flow 

temperature can be modified by selecting the 

functioning curve via the selector switch (4) 

(or on the CAR

V2

  control panel, if connected 

to the boiler) selecting a value from “0 to 9”.

  With external probe present, the relative 

symbol (18) will appear on the display. In the 

central heating phase, if the temperature of the 

water contained in the system is sufficient to 

heat the radiators, the boiler can only function 

with the activation of the pump.

 

“Stand-by” mode.

 Press button (6) repeatedly 

until the symbol (

) appears. From now on 

the boiler remains inactive and the anti-freeze 

function, pump anti-block function and 3-way 

and signalling of any anomalies is guaranteed.

 

N.B.:

 in these conditions the boiler is still 

powered.

 

“Off” mode.

 By holding the button (6) down 

for 8 seconds, only the central point remains lit 

on the display, and the boiler is off completely. 

The safety functions are not guaranteed in this 

mode.

 

N.B.:

 in these conditions the boiler is consid-

ered still live even if there are no functions 

active.

 

“Automatic vent” mode.

 When the function 

is enabled, every time the boiler is electrically 

powered, the system automatic vent function 

is activated (lasting 8 minutes). This function 

is displayed via a countdown signalled by the 

indicator (14). During this period the DHW 

and CH functions are not active.

  The “automatic vent” can be annulled by press-

ing the “reset” button (2).

 

Display operation.

 The display lights up while 

the control panel is being used; after a set in-

activity period, the brightness drops until only 

the active symbols are displayed. The lighting 

mode can be varied via parameter t8 in the 

P.C.B. programming menu.

Содержание Victrix Maior 28 TT 1 ErP

Страница 1: ...VICTRIX MAIOR 28 35 TT 1 ERP IE Instruction and recommendation booklet 1 038659ENG...

Страница 2: ......

Страница 3: ...onal limits established by the Law Installation and maintenance must be performed in compliance with the regulations in force according to the manufacturer s instructions and by an authorised company...

Страница 4: ...on recommendations 5 1 2 Main dimensions 6 1 3 Antifreeze protection 6 1 4 Boiler connection unit 7 1 5 Gas connection 7 1 6 Hydraulic connection 7 1 7 Electric connection 8 1 8 Remote controls and ro...

Страница 5: ...boilerforpossiblewater and flue removal connections Keep all flamma ble objects away from the appliance paper rags plastic polystyrene etc Do not place household appliances underneath the boiler as th...

Страница 6: ...ary with respect to the minimum temperature at which the system must be kept An aqueous solution must be made with potential pollution class of water 2 EN 1717 2002 or local regula tions in force Atte...

Страница 7: ...n compliance with the tech nical standards in force in order to protect the system and the appliance from deposits e g scale slurry or other hazardous deposits In order not to void the heat exchanger...

Страница 8: ...d assembly instructions contained in the acces sory kit On Off Immergas digital chrono thermostat The chrono thermostat allows set two room temperature value one for daytime comfort temperature and on...

Страница 9: ...e always operates when con nected regardless of the presence or type of room chrono thermostat used and can work in combi nation with Immergas chrono thermostats The correlation between system flow te...

Страница 10: ...ctor allowed corresponds to the resistance encountered with the maximum allowed pipe length for each type of Terminal Kit This information allows calculations to be made to verify the possibility of s...

Страница 11: ...Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric vertical intake exhaust terminal 60 100 Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust m...

Страница 12: ...s present in the kit positioning the relevant gaskets Engage the 90 80 bend with the male end smooth in the female end with lip seal of the 80 flange unit until it stops Introduce the gasket making it...

Страница 13: ...the circular projections down wards in contact with the boiler flange and tighten using the screws present in the kit Fit the 60 100 3 concentric terminal pipe with the male side smooth to the female...

Страница 14: ...cal length of 14 4 m including the terminal This configuration corresponds to a resistance factor of 100 In this case specific extensions must be requested Vertical kit with aluminium tile 80 125 Kit...

Страница 15: ...t Remove the flat flange present in the lateral hole with respect to the central one ac cording to needs and replace it with the flange 3 positioningthegasket 2 alreadypresentin the boiler and tighten...

Страница 16: ...xternal pipe must be fitted on the adaptor until it stops 1 N B to encourage the removal of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a minimum slope of 1...

Страница 17: ...ed inside buildings in 23 or B53 mode in this case all technical rules and national and local regulations in force must be complied with type B open chamber boilers must not be installed in places whe...

Страница 18: ...non treated water To prevent corrosion the water system s PH should be between 6 5 and 8 5 Check the maximum content of chlorides which should be less than 250 mg l N B for quantities and methods of u...

Страница 19: ...ble to the system Head kPa A B Head available with by pass closed B Head available with by pass open C D Power absorbed by the pump with by pass open dotted area D Power absorbed by the pump with by p...

Страница 20: ...ty the entire system Moreover the version with filter preserves the functioning characteristics of the boiler thanks to its inspectionable filter Polyphosphate dispenser kit on request The polyphospha...

Страница 21: ...check that the air intake flue exhaust terminals if fitted are not blocked If temporary shutdown of the boiler is required proceed as follows a drain the heating system if antifreeze is not used b shu...

Страница 22: ...perating mode This function is always active and combined with the Solar ignition delay with time set above 0 seconds it manages the ignition of the boiler according to the domestic hot water inlet te...

Страница 23: ...e on and off again the 5 attempts are re acquired 10 Insufficient system pressure Water pressure inside the central heating circuit that is sufficient to guarantee the correct operation of the boiler...

Страница 24: ...ment it is only possible to control the system by means of the control panel of the boiler itself Check operation of the Wireless CAR checkthebatterycharge refertotherelative instructions booklet 59 M...

Страница 25: ...ler restarts without having to be reset 98 Block maximum no of software errors The maximum number of software errors possible has been reached Press the Reset button 1 99 General block A boiler anomal...

Страница 26: ...osed 2 10 ANTI FREEZE PROTECTION The Victrix Maior 28 35 TT 1 ErP series boiler has an anti freeze function that switches the burner on automatically when the temperature falls below 4 C standard prot...

Страница 27: ...commission the boiler ensure that the type of gas used corresponds to the boiler settings the type of gas appears on the display on first electrical power supply or by checking the relative parameter...

Страница 28: ...ow probe B2 Domestic hot water probe B4 External probe optional B5 Return probe B6 Domestic hot water flow meter B9 Domestic hot water inlet probe B10 Flue probe B24 Safety flow probe E3 Ignition and...

Страница 29: ...closed and also the functionality of the pump Drain trap clogged This may be caused by dirt or combustion products deposited inside Check that there are no residues of material blocking the flow of co...

Страница 30: ...o clock position Fig 3 5 and press the Reset button for about 8 seconds until the chimney sweep function is activated then press the summer winter button within 3 seconds Nominalheatoutput with the f...

Страница 31: ...3 seconds 3 9 Once the function is active the boiler sequential ly carries out the procedures required to calibrate the appliance with the nominal intermediate and minimum heat output values At this...

Страница 32: ...fgas parameter G and by restoring it according to the actual operating conditions wait for approximately 10 seconds between the gas change and the when it is restored 3 13 The restored values will be...

Страница 33: ...odel 6 Do not use on this boiler model 7 Do not use on this boiler model 0 7 1 P4 Relay 2 optional The boiler is set up for functioning with the relay P C B optional which can be configured 0 Off 1 Ge...

Страница 34: ...hanging the operating mode in order to quickly and comfortably satisfy an additional request for domestic hot water 0 100 seconds step 10 sec 2 t5 Central heating ignitions timer The boiler has electr...

Страница 35: ...ised value F0 Equivalent length flue Defines the length of the flue see par 3 11 0 2 0 F1 Not used on this boiler model In the event of an alteration anomaly E72 appears and fast calibration is requir...

Страница 36: ...the sealed chamber Check contents of the condensate drain trap Check that there are no residues of material clogging the condensate passage also check that the entire condensate drainage circuit is cl...

Страница 37: ...o screws a 2 Press the hooks inwards which block the lower grid b 3 remove the grid b Front panel Fig 3 15b 4 Open the protection door e1 pulling it towards you 5 Remove the cover caps c and loosen sc...

Страница 38: ...STALLER USER MAINTENANCE TECHNICIAN Ref X Control panel Fig 3 15d 9 Press the hooks on the side of the control panel i 10 Tilt the control panel i towards you Sides Fig 3 15e 11 Loosen screws k of sid...

Страница 39: ...2 1 09 0 80 9 0 7740 28 0 98 0 72 8 0 6880 24 0 87 0 64 7 0 6020 19 0 76 0 56 6 0 5160 15 0 65 0 48 5 0 4300 10 0 54 0 40 4 0 3440 6 0 44 0 32 3 0 2580 4 0 33 0 24 2 8 2408 1 0 30 0 22 Victrix Maior 3...

Страница 40: ...25 Flue temperature at nominal output C 51 52 Flue temperature at minimum output C 45 45 Victrix Maior 35 TT 1 ErP Gas nozzle diameter mm 6 15 6 15 Flue flow rate at nominal heat output kg h 55 56 Flu...

Страница 41: ...loss at flue with burner On Off 80 60 C 0 02 2 00 0 01 2 00 Central heating circuit max operating pressure bar 3 3 Maximum heating temperature C 90 90 Adjustable heating temperature max operation fie...

Страница 42: ...N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH maximum heat i...

Страница 43: ...means 60 C on return and 80 C on flow Low temperature mode for condensation Boilers means 30 C for low temperature boilers 37 C and for other appliances 50 C of return tempera ture Model s Victrix Mai...

Страница 44: ...tion AFC 17 GJ Seasonal space heating energy efficiency s 93 Water heating energy efficiency wh 85 Parameter value Annual energy consumption for the heat ing function QHE 58 4 GJ Annual electricity co...

Страница 45: ...fiche of boiler Supplementary heat pump From fiche of heat pump Solar contribution and Supplementary heat pump Select smaller value Boiler and supplementary heat pump installed with low temperature he...

Страница 46: ...om fiche of heat pump The energy efficiency of the package of products provided far in this fiche may not correspond to its actual energy efficiency once installed in a building as the efficiency is i...

Страница 47: ...contribution From fiche of solar device 1 I 2 1 1 x I 10 x II III I Auxiliary electricity 3 G F E D C B A A A A 27 27 27 28 27 27 27 28 30 30 30 32 33 34 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100...

Страница 48: ...ing energy efficiency under colder and warmer climate conditions Colder 0 2 x Warmer 0 4 x Declared load profile Solar contribution From fiche of solar device 1 ___ 2 1 1 x ___ 10 x ___ ____ ____ Auxi...

Страница 49: ...49...

Страница 50: ...50...

Страница 51: ...51...

Страница 52: ...mmergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038659ENG rev ST 001862 004 07...

Отзывы: