background image

System  

Manager Kit

Electronic control

Instructions and 

warnings

Installer

User

Maintenance technician

IE

Содержание System Manager Kit

Страница 1: ...System Manager Kit Electronic control Instructions and warnings Installer User Maintenance technician IE...

Страница 2: ......

Страница 3: ...e constant efficiency of your System Manager Kit We would like to provide you with some important indications your observance of which will ensure your satisfaction with the Immergas product Read the...

Страница 4: ...ture setting 12 2 2 Domestic hot water temperature setting on boiler side 13 2 3 Setting comfort and reduced room temperature 13 2 4 User settings 14 2 5 Programming operating time in comfort mode 15...

Страница 5: ...in systems with puffer 65 9 20 System manager three way integration connection in systems with puffer 66 9 21 System manager expansion zone pump connection 67 9 22 System manager expansion zone flow p...

Страница 6: ...Manager Kit and must be keptforfuture reference The System Manager Kit is intended only for the use for which it has been expressly designed Any other use must be considered improper and therefore dan...

Страница 7: ...play N B Some buttons can have different meanings and functions depending on the displayed context 1 DESCRIPTIONS OF CONTROLS 1 1 BUTTONS DESCRIPTION Thebutton 1Fig 1 1 allowsyoutochangetheoperating m...

Страница 8: ...be temperature Alarms records Assistance menu The button Ref 3 Fig 1 1 allows you to move back from a current menu to the previous one The buttons Ref 4 and 5 Fig 1 1 are used to cyclically scroll thr...

Страница 9: ...ing button the status changes sequen tially from stand by to summer operation summer with cooling winter and party The antifreeze function is also provided in the mode stand by summer and winter 1 4 1...

Страница 10: ...red is above that set the system can switch on 1 4 4 Operation in winter mode Pressing button switches to winter operation the System Manager Kit enables both domestic hot water production and room ce...

Страница 11: ...ze function has maximum priority with respect to other settings When ambient temperature drops below 5 C a central heating request at minimum setting is made This situation remains active until there...

Страница 12: ...to the main screen Set manual it lets you set the DHW set point valid until the next time range change water T it displays in real time the domestic hot water temperature Dhw time slots enables only...

Страница 13: ...ng menu 01 SET POINT Fig 2 4 N a v i g a t i o n m e n u 06 SERVICE 01 SET POINT 02 USER SETTING Press button to enter the first room set Summer S e t r o o m S 0 2 SUMMER WITH FREEZ ZN 2 Comfort 25 0...

Страница 14: ...F1 000 00 c kWh Elet F2 000 00 c kWh Elet F3 000 00 c kWh Fig 2 9 Electricity prices It lets you enter electricity prices U s e r s e t t i n g D 0 4 Energy band time Tariff Two part F1 00 00 00 00 F...

Страница 15: ...utton twice to go back to the main screen Fancoil in winter The option exclusively allows fan coils to be used in winter operation mode This option may only be selected if it is provided for in the sy...

Страница 16: ...ter the menu Scroll through screens with buttons until access ing the menu Program for zone 1 Fig 2 18 Time slots Calendars from 1 to 4 are assigned to Zones and DHW in these menus Therefore each day...

Страница 17: ...is set at 5 C all zones to control ambient antifreeze All operating modes for controlling the solar heating system will remain active if activated in the configuration menu At the end press button twi...

Страница 18: ...e of a request from a zone is highlighted with an asterisk Info I02 FLOW SET POINT System 12 5 C Zone 01 12 5 C Zone 02 14 1 C Fig 3 3 Dew point Info I03 DEW POINT Zone 01 00 0 C Fig 3 4 DHW temperatu...

Страница 19: ...e Cooling Frequency 00 0 Hz Fig 3 10 Machine efficiency Info I16 COP calculation Minimum 02 00 Active 02 93 Fig 3 11 Machine efficiency Info I16 COP calculation Minimum 02 00 Audax 1 02 93 1 3 52 2 2...

Страница 20: ...nomalies Boiler anomaly Disabled solar operation Dehumidifier fault Ambient and humidity probe fault for all zones If no alarm has been triggered it is still possible to view the Alarms log by proceed...

Страница 21: ...ITALIAN Fig 5 2 Press the button again to make the language that requires changing to flash Press the arrows to select the desired language At the end press the button to go back to the AS SISTENZA AS...

Страница 22: ...rameters System definition Within this menu it is possible to set the features of the system that need to be managed Press the arrows and select 04 System Defini tion Press the button to enter the sub...

Страница 23: ...dew point calculation intended to elimi nate any formation of condensation Yes No This option is not included in the high temperature zone Enabling dehumidifier Yes No This option is not included in t...

Страница 24: ...trol a 3 way valve to choose whether to use the central heating system or the cooling one Enable generator switch off It lets you switch off all generators via an external control Yes No This function...

Страница 25: ...it is possible to activate external probe operation and it will also be possible to select the points where central heating and cooling will operate Press the arrows and select 06 Regulation Press the...

Страница 26: ...DHW circuit It is possible to set a separate or common control for DHW management D H W Q 0 2 Sanitary circuit type Sanitary circuit Split Fig 5 28 R e g u l a t i o n T 0 5 External temp limit Heatin...

Страница 27: ...ion menu Install a second solar pump only if there is only one heat pump system decoupling disabled system probe not installed Press the arrows and select 08 Solar system Press the button to enter the...

Страница 28: ...s Min T 10 0 C Fig 5 36 Enable Yes No T min 10 90 C the solar circuit pump is enabled to start operating only if the temperature set on the manifold is reached S o l a r s y s t e m W 0 8 Collector AN...

Страница 29: ...Prior san time 180 m Prior heat time 240 m Fig 5 41 Settings It allows setting DHW wait time It is the maximum wait time before activating the DHW integration Central heating wait time It is the maxi...

Страница 30: ...section it is possible to reset the operation hour counter for the heat pump the source of integration and solar circuit 1 and 2 Press the arrows and select 10 Reset hour meter Press the button to en...

Страница 31: ...the activation of an individual heat pump is determined according to the flow tem perature of the heat pumps in set configuration and to the heating set If the flow temperature of the heat pumps is lo...

Страница 32: ...ode Activat time 000 min Deactiv time 000 min Fig 5 56 DHW mode In case of DHW request it corresponds to the wait time before the activation of a machine Cascade parameter C04 Sanitary mode Activat ti...

Страница 33: ...ntation Audax Top Type 6 8 12 16 ErP New address to assign 12 Configure Yes i Fig 5 59 Type select the Audax Top type Audax Top 6 8 12 16 ErP Audax Top 18 21 ErP New address Set the new address value...

Страница 34: ...0 M08 Set SHT Room temp 5 0 35 0 C 20 M08 Set ZHT Flow Temp 5 85 C C 25 M08 ZHT Flow Offset 15 15 C 0 Set room menu n parameter Description Range adjustment Value default Value customis S01 Set comfo...

Страница 35: ...04 Slot 2 ON 00 00 24 00 19 00 D04 Slot 3 ON 00 00 24 00 23 00 D05 Heat pump manual disabling Yes No No D05 Heat pump temporary enabling Yes No No D06 HP enabling Monday CAL1 CAL2 CAL3 CAL4 CAL1 D06 H...

Страница 36: ...alendar 2 Slot 2 OFF 0 24 0 45 13 00 K03 Calendar 2 Slot 3 ON 0 24 0 45 17 00 K03 Calendar 2 Slot 3 OFF 0 24 0 45 23 00 K03 Calendar 2 Slot 4 ON 0 24 0 45 00 00 K03 Calendar 2 Slot 4 OFF 0 24 0 45 00...

Страница 37: ...L1 K07 Zone 2 Thursday CAL1 CAL2 CAL3 CAL4 CAL1 K07 Zone 2 Friday CAL1 CAL2 CAL3 CAL4 CAL1 K07 Zone 2 Saturday CAL1 CAL2 CAL3 CAL4 CAL1 K07 Zone 2 Sunday CAL1 CAL2 CAL3 CAL4 CAL1 K08 Zone 3 Monday CAL...

Страница 38: ...DHW Sunday CAL1 CAL2 CAL3 CAL4 CAL1 K11 Holiday start day 1 31 1 K11 Holiday start month 1 12 8 K11 Holiday start year 0 99 16 K11 Holiday end day 1 31 31 K11 Holiday end month 1 12 8 K11 Holiday end...

Страница 39: ...No P05 Humidistat No Yes No P05 P Dew Point No Yes No P05 En Dehumid No Yes No P06 Mode Hot Cold Hot Cold Hot P06 Zone name BEDROOMS P06 Disp Absent Rem Control Remote panel Zone Control Temp humid p...

Страница 40: ...75 P17 Mode Max sp Modul Modul P17 Speed Minimum 19 50 50 P17 Speed Maximum 50 100 100 P17 Delta T 2 20 5 P18 Reduction enabling No Yes No P18 Power in reduced 50 100 75 P19 Mode Max sp Modul Modul P...

Страница 41: ...25 T02 Set zone 1 maximum flow 30 85 45 T03 External probe No Yes No T03 Set zone 2 minimum flow 25 50 25 T03 Set zone 2 maximum flow 30 85 45 T04 External probe No Yes No T04 Set zone 3 minimum flow...

Страница 42: ...nnection DT 1 20 6 W01 Pump 1 disconnection DT 0 5 19 5 4 W02 Pump 2 connection DT 1 20 6 W02 Pump 2 disconnection DT 0 5 19 5 4 W03 Maximum tank temperature 20 90 70 W04 Tank cooling enabling Yes No...

Страница 43: ...Modem RS 232 Modbus Winload Winload B01 Baudrate 1200 2400 4800 9600 19200 19200 B01 Address 1 100 1 Assistance Heat pump set menu n parameter Description Range adjustment Value default Value customi...

Страница 44: ...pressing the last key or press SLEEP 45 seconds after pressing the last key the name of the parameter or the numerical value will flash If the parameters regarding communication Ad01 arechanged commun...

Страница 45: ...by and displays the operating modes the room temperature and the time Select operating mode By pressing the Mode button one can select the operating mode of the system in cyclic mode between Summer w...

Страница 46: ...FF mode oFF that allows to switch the boiler off in the pre set time interval Repeat the operations for all the time slots and for the days required To exit the time slot programming mode wait for a f...

Страница 47: ...the display of the humidity one can change the desired humidity value simply by turning the main selector Fig 7 9 Fig 7 10 By pressing the new selector the zone flow set and the system active dhw set...

Страница 48: ...on at the bottom left corner Fig 7 12 Also depending on the system s configuration the main screendisplaysvariousinformationregardingthesystem amongst which State Description nn Room humidity value nn...

Страница 49: ...settomanagethe room temperature of the zone if required it is possible to change the value manually for a determined range Turning the main switch changes the room tempera ture and pressing it confirm...

Страница 50: ...single day or to a group of days single day Monday Friday Saturday Sunday Monday Saturday Monday Sunday Thereforeeachdaymaybepersonalisedwith4different operating programs For convenient selection the...

Страница 51: ...cted menu dedicated to a qualified technician Language Defines the remote panel operation language Zone Set Point Menu Menu item Description Range Default Customised value Set central heating comfort...

Страница 52: ...external probe optional Calculated set system temperature Flow temperature requested by the generators Board software version System software revision Display software version Display software revisi...

Страница 53: ...AGIS COMBO The A11 T02 parameters and the parameter families UXX RXX IXX are automatically set by the system manager Settings required A12 OFF A13 1 A21 11 A22 OFF P06 IN The ranges of integration and...

Страница 54: ...nabled Manual management A11 Audax Top 18 21 N 1 circulation pump test circulation pump sp 000 Flow switch No Fig 8 5 The parameters are Circ pump override Enables the circulation pump to be manually...

Страница 55: ...ax power 8VA 6W input voltage 24Vac 10 15 50 60Hz 48Vdc 36Vmin 71Vmax J5 X N G x R x T D N G x R x T J6 A13 T1 T1 trasformatore 230 Vac 24Vac B1 B2 J7 J8 ISOLATED J9 J10 TLAN GND Y1 Y2 GND NO2 C2 PWM...

Страница 56: ...Magis Pro Fig 9 4 9 4 SYSTEM MANAGER CONNECTION TO MAGIS PRO AND MAGIS COMBO Key A13 System manager A25 Audax Pro Modbus type connection AWG 20 22 type shielded cable Modbus type connection AWG 20 22...

Страница 57: ...2 40 41 Fig 9 6 9 6 SYSTEM MANAGER CONNECTION TO SUPERIOR ERP BOILER THROUGH EXTERNAL PROBE INPUT Key A13 System manager A3 Boiler P C B Note Set selector switch S34 to OFF to enable connection to the...

Страница 58: ...ax J5 X N G x R x T D N G x R x T J6 J7 J8 ISOLATED J9 J10 TLAN GND Y1 Y2 GND NO2 C2 PWM 0 10V 39 38 A3 A3 X9 X11 X10 Fig 9 8 9 8 SYSTEM MANAGER CONNECTION TO VICTRIX EXA BOILER THROUGH EXTERNAL PROBE...

Страница 59: ...ac GND T T VG VG0 Y1 J5 NC1 C1 B1 J3 J4 Serial Address J9 B3 Vdc GND 2 J 1 J 5V Ref B4 NO1 B2 GND 5V Ref Vdc J10 J8 NC4 C4 NO4 J7 NC3 C3 NO3 J6 NC2 C2 NO2 1 2 4 8 A15 ID1 ID2 ID3 ID4 IDC1 G G0 24Vac G...

Страница 60: ...R EXPANSION COMMUNICATION CABLE CONNECTION Key A13 System manager A15 Expansion 1 Note Connection example of communication cable to expansion 1 In case of connection to other expansions configure the...

Страница 61: ...OF THERMAL SOLAR SYSTEM Key A13 System manager M6 Solar circulator pump B11 Solar collector probe B12 Solar storage tank probe low Input for generic boiler alarm Fig 9 11 9 11 SYSTEM MANAGER TA REQUES...

Страница 62: ...B1 B2 B3 B4 B5 B6 GND SYNC G GD 5Vref VDC ID1 GND C1 NC1 NO1 J1 J2 J3 max power 8VA 6W input voltage 24Vac 10 15 50 60Hz 48Vdc 36Vmin 71Vmax J5 X N G x R x T D N G x R x T J6 J7 J8 ISOLATED J9 J10 TL...

Страница 63: ...0 Vac ALIMENTAZIONE A al bollitore B all impianto L AB M50 B2 T T VG VG0 Y1 J5 NC1 C1 B1 J3 J4 Serial Address J9 B3 Vdc GND 2 J 1 J 5V Ref B4 NO1 B2 GND 5V Ref Vdc J10 J8 NC4 C4 NO4 J7 NC3 C3 NO3 J6 N...

Страница 64: ...LAN GND Y1 Y2 GND NO2 C2 PWM 0 10V Alimentazione R2 R3 B2 50 Hz 230 24 Vac ALIMENTAZIONE R3 R2 400 N 230Vac unit bollitore Resistenza integrativa 50 Hz Key A13 System manager B2 Storage tank probe R2...

Страница 65: ...5V Ref Vdc J10 J8 NC4 C4 NO4 J7 NC3 C3 NO3 Key A13 System manager A15 4 Address 4 zone expansion kit M10 Puffer spillage pump B13 Puffer probe Note Configure the expansion address as indicated A13 B1...

Страница 66: ...pen switch to PdC Closed switch to boiler Command K4 Open switch to PdC Closed switch to boiler We recommend applying 2 integration valves 6 24 V A2 A1 14 11 12 T T VG VG0 Y1 J5 NC1 C1 B1 J3 J4 Serial...

Страница 67: ...0 Zone pump Note Configure the expansion address as indicated Fig 9 22 9 22 SYSTEM MANAGER EXPANSION ZONE FLOW PROBE CONNECTION Key A15 Zone expansion kit B3 Zone flow probe Note Configure the expansi...

Страница 68: ...2 3 4 1 2 4 8 1 2 3 4 1 2 4 8 Key A15 zone expansion kit A17 room temperature humidity sensor kit Note Configure the expansion address as indicated For the electrical connections we recommend using 3...

Страница 69: ...J 5V Ref B4 NO1 B2 GND 5V Ref Vdc J10 1 2 4 8 Address ON Indirizzo 4 Indirizzo 3 Indirizzo 2 Serial Indirizzo 1 Espansione Indirizzi ON 1 2 3 4 1 2 4 8 ON 1 2 3 4 1 2 4 8 ON 1 2 3 4 1 2 4 8 1 2 3 4 1...

Страница 70: ...nsion address as indicated 6 24 V A2 A1 14 11 12 T T VG VG0 Y1 J5 NC1 C1 B1 J3 J4 Serial Address J9 B3 Vdc GND 2 J 1 J 5V Ref B4 NO1 B2 GND 5V Ref Vdc J10 J8 NC4 C4 NO4 J7 NC3 C3 NO3 J6 NC2 C2 NO2 1 2...

Страница 71: ...Address J9 B3 Vdc GND 2 J 1 J 5V Ref B4 NO1 B2 GND 5V Ref Vdc J10 J8 NC4 C4 NO4 J7 NC3 C3 NO3 J6 NC2 C2 NO2 1 2 4 8 ON 1 2 3 4 ID1 ID2 ID3 ID4 IDC1 G G0 24Vac GND A15 4 Serial Espansione Indirizzi Y6...

Страница 72: ...Vdc GND 2 J 1 J 5V Ref B4 NO1 B2 GND 5V Ref Vdc J10 J8 NC4 C4 NO4 J7 NC3 C3 NO3 J6 NC2 C2 NO2 1 2 4 8 ON 1 2 3 4 ID1 ID2 ID3 ID4 IDC1 G G0 24Vac GND 50 Hz 230 Vac ALIMENTAZIONE L N M7 B22 B23 A15 5 O...

Страница 73: ...UDAX TOP ErP 1 poli di colore grigio Morsettiera a cinque AUDAX TOP ErP 3 poli di colore grigio Morsettiera a cinque AUDAX TOP ErP 2 poli di colore grigio Morsettiera a cinque Fig 9 31 9 31 SYSTEM MAN...

Страница 74: ...TLAN GND Y1 Y2 GND NO2 C2 PWM 0 10V n 4 AUDAX TOP 18 21 ErP 32 33 33 34 35 36 35 34 33 33 32 n 1 AUDAX TOP 18 21 ErP 36 35 34 33 33 32 n 2 AUDAX TOP 18 21 ErP 36 35 34 33 33 32 n 3 AUDAX TOP 18 21 ErP...

Страница 75: ...TLAN GND Y1 Y2 GND NO2 C2 PWM 0 10V Fig 9 33 9 33 SYSTEM MANAGER CONNECTION TO HUMIDISTAT Key A15 Zone expansion kit S50 Zone humidistat On Off Note Configure the expansion address as indicated T T VG...

Страница 76: ...WM 0 10V Fig 9 36 9 36 SYSTEM MANAGER CONNECTION TO PLATE EXCHANGER DOWNSTREAM OF HEAT PUMP Key A15 5 Zone expansion kit with address 5 K4 Relay type EMR 12 V dc M11 Pump downstream of the plate heat...

Страница 77: ...the expansion address as indicated NO3 C3 NC3 J7 NO2 C2 NC2 J6 FV 24Vac 50Hz Alimentazione A15 5 ON 1 2 3 4 1 2 4 8 Espansione Indirizzi Indirizzo 5 Serial Address ID1 ID2 ID3 ID4 IDC1 G G0 24Vac GND...

Страница 78: ...0 60 Hz GND NO2 L N GND Y2 50 Hz 230 Vac ALIMENTAZIONE A20 1 A20 2 Y1 A20 3 A20 4 PWM 0 10V C2 TLAN J10 J9 A13 J5 XNG xR xT DNG xR xT J6 J7 J8 ISOLATED Key A13 System manager A20 1 A20 4 Zone remote c...

Страница 79: ...YSTEM MANAGER CONNECTION TO ZONE REMOTE PANELS A13 B1 B2 B3 B4 B5 B6 GND SYNC G GD 5Vref VDC ID1 GND C1 NC1 NO1 J1 J2 J3 max power 8VA 6W input voltage 24Vac 10 15 50 60Hz 48Vdc 36Vmin 71Vmax J5 X N G...

Страница 80: ...owing configurations ID1 ID2 ID3 Stand by 0 0 0 Winter 1 0 0 Summer 1 1 0 Cooling 0 0 1 Party 1 0 1 4 1 2 3 ALARM IN A26 Address Serial Indirizzo 5 Espansione Indirizzi 50Hz Alimentazione 24Vac A15 ID...

Страница 81: ...ax J5 X N G x R x T D N G x R x T J6 J7 J8 ISOLATED J9 J10 TLAN GND Y1 Y2 GND NO2 C2 PWM 0 10V Serial Card 1 gnd GND Note Communication protocols Winload Carel Modbus A13 B1 B2 B3 B4 B5 B6 GND SYNC G...

Страница 82: ...A0114 Incorrect configuration of digital Supervision inputs A0115 Expansion 5 off line alarm A0116 Audax 2 off line alarm A0117 Audax 3 off line alarm A0118 Audax 4 off line alarm A0119 Audax Top conf...

Страница 83: ...83...

Страница 84: ...red data refers to new products that are correctly installed and used in accordance with applicable regulations NOTE correct periodic maintenance is highly recommended immergas com Torequestfurtherspe...