59
INS
TALLER
U
SER
M
AINTEN
AN
CE
TECHNI
CI
AN
TECHNI
CAL
D
AT
A
4.3 TECHNICAL DATA TABLE
Domestic hot water nominal heat input
kW (kcal/h)
23.8 (20502)
Central heating nominal heat input
kW (kcal/h)
23.8 (20502)
Minimum heat input
kW (kcal/h)
9.8 (8423)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
22.6 (19436)
Central heating nominal heat output (useful)
kW (kcal/h)
22.6 (19436)
Minimum heat output (useful)
kW (kcal/h)
9.1 (7826)
*Effective thermal efficiency 80/60 Nom./Min.
%
94.8 / 94.8
*Effective thermal efficiency 50/30 Nom./Min.
%
101.6 / 100.5
*Effective thermal efficiency 40/30 Nom./Min.
%
102.3 / 100,5
Casing losses with burner On/Off (80-60°C)
%
0,59 / 4,70
Chimney losses with burner On/Off (80-60°C)
%
0,01 / 0,50
Central heating circuit max. operating pressure
bar (MPa)
3,0 (0,30)
Maximum heating temperature
°C
90
Adjustable central heating temperature (min. operating field)
°C
38
Adjustable central heating temperature (max operating field)
°C
85
System expansion vessel total volume
l
4.2
Expansion vessel pre-charged pressure
bar (MPa)
1,0 (0,10)
Appliance water content
l
2
Head available with 1000 l/h flow rate
kPa (m H2O)
21,7 (2,2)
Hot water production useful heat output
kW (kcal/h)
22.6 (19436)
Domestic hot water adjustable temperature
°C
30-60
Domestic hot water circuit min. pressure (dynamic)
bar (MPa)
0,3 (0,03)
Domestic hot water circuit max. operating pressure
bar (MPa)
10,0 (1,00)
Flow rate capacity in continuous duty (∆T 30°C)
l/min
11.4
Weight of full boiler
kg
32.8
Weight of empty boiler
kg
30.8
Electrical connection
V/Hz
230 / 50
Nominal power absorption
A
0.65
Installed electric power
W
100
Pump absorbed power
W
41
EEI value
-
≤0,20 - Part. 3
Fan power absorbed power
W
47
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
Max. flue overheating temperature
°C
120
Ambient operating temperature range
°C
-5 ÷ +40
Ambient operating temperature range with optional antifreeze kit
°C
-15 ÷ +40
NOX class
-
6
Weighted NOX
mg/kWh
26
Weighted CO
mg/ppm
49
Type of appliance
-
C12-C12x-C32-C32x-C42-
C42x-C52-C52x-C62-C62x-
C82-C82x-C92-C92x
B22p-B32-B52p
Category
-
II 2H3P
The data relating to domestic hot water performance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15°C; the values
are measured immediately at the boiler outlet, considering that to obtain the data declared, mixing with cold water is required.
* The efficiency values refer to the lower calorific value.
The weighted NOx value refer to the net calorific value.