Id
Parameter
Parameter
Description
Range
Default
Value
value
P10
Ignition power
Establishes the power at which the boiler must switch on.
The 1st gas valve step soft ignition step can be set. The
ignition power increases as the parameter value is increased.
00 - 40
00 = Methane
20 - GPL
P11
Minimum
heating setting
Defines the minimum flow temperature.
38 - 55 °C
38 °C
P12
Maximum
heating setting
Defines the maximum flow temperature.
38 - 85 °C
85 °C
P13
Temperature
gradient
Change the insufficient circulation intervention value (E27)
(Attention: do not change this parameter)
00 - 15
11
(0 = Function
deactivated)
P14
Pump functio-
ning
The pump can work in two ways:
OFF intermittent: in “Winter” mode the pump is managed
by the room thermostat or by the remote control.
ON continuous: in "winter" mode the pump is always
powered and is therefore always in operation.
oF - on
oF
P15
Gas valve
calibration
Allows to perform the calibration of the gas valve
5 = full calibration
different from 5 = calibration correction
00 - 20
00
P16
Valve check
Attention: do not change this parameter.
00 - 02
02
P17
Flow off
temperature
increase (central
heating)
Increases the flow off temperature at ignition only in the first
30 seconds.
00 = Function
deactivated
01
01 = Function
activated
P18
Ignition phase
no. of fan revs
Defines the operating speed of the fan during the ignition
phase (Attention: the number of revs must not be changed)
200 - 220
(x10 = RPM)
210
(x10 = RPM)
P19
Minimum no. of
fan revs
Defines the operating speed of the fan at minimum power
(Attention: the number of revs must not be changed)
185 - 205
(x10 = RPM)
195
(x10 = RPM)
P20
Maximum no. of
fan revs
Defines the operating speed of the fan at maximum power
(Attention: the number of revs must not be changed)
270 - 300
(x10 = RPM)
290
(x10 = RPM)