3.4 INFORMATION MENU.
Pressing the buttons (3 and 4) for 5 seconds, the
“Information menu” is activated, which allows
to display some boiler functioning parameters.
To scroll through the various parameters, press
(3 and 4), to exit from the menu press buttons
(3 and 4) again for 5 seconds or press button (2)
for 5 seconds or wait for 60 seconds.
List of parameters.
N°
parameter
Description
d1
Displays the flame signal (uA).
d2
Displays the primary exchanger
output instant heating flow
temperature.
d3
Displays the instant output
temperature from the DHW
exchanger.
d4
Displays the temperature set for
the central heating set (if remote
control is present).
d5
Displays the temperature set for
the DHW set (if remote control
is present).
d6
Displays the external environ-
ment temperature (if the exter-
nal probe is present).
If the temperature is below zero,
the value is displayed flashing.
3.5 PROGRAMMING THE P.C.B.
The boiler is prepared for possible programming of
several operation parameters. By modifying these
parameters as described below, the boiler can be
adapted according to specific needs.
To access the programming phase, proceed as
follows:
- press buttons (1) and (2) at the same time for
approximately 8 seconds;
- Using buttons (3) and (4), select the param-
eter to be changed indicated in the following
table:
List of
param-
eters
Description
P1
Boiler mode (DO NOT USE)
P2
Display lighting
P3
DHW thermostat
P4
Minimum CH output
P5
Maximum CH output
P6
Central heating ignitions timer
P7
Central heating ramp timer
P8
Heating switch-on delay
request from room thermostat
and remote control
P9
Solar mode
- adjust the corresponding value consulting the
table using buttons (5) and (6);
- confirm the set value pressing the Reset button
(1) for approximately 3 seconds; by pressing
keys (3) and (4) at the same time exit the func-
tion without memorising the modifications
made.
N.B.:
after a period of time, without touching
any keys, the operation cancels automatically.
Boiler mode.
It establishes whether the boiler
functions in instant or storage mode.
Boiler mode (P1)
Range of values which can
be set
Standard
setting
0 - instant boiler
1 - boiler with storage tank
0
Illuminazione display.
Stabilisce la modalità di
illuminazione del display.
Display lighting (P2)
Range of values which can
be set
Standard
setting
0 - Off
1 - Auto
2 - On
1
- Off:
the display is always lit with low inten-
sity.
- Auto:
the display lights up during use and low-
ers after 15 seconds of inactivity. In the case of
anomaly the display flashes.
- On:
the display is always lit with high inten-
sity.
DHW thermostat.
With the “correlated” ther-
mostat setting, boiler switch-off takes place on
the basis of the temperature set. While with
the setting of the “fixed” DHW thermostat the
switch-off temperature is fixed at the maximum
value independently from the value set on the
control panel.
DHW thermostat (P3)
Range of values which can
be set
Standard
setting
0 - Fixed
1 – Correlated
1
Heating output.
The boiler also has electronic
modulation that adapts the boiler potentiality to
the effective heating demand of the house. Then
the boiler works normally in a variable gas pres-
sure field between the minimum heating power
and the maximum heating power depending on
the system’s heating load.
N.B.:
the boiler is produced and calibrated in
the central heating phase at nominal output.
Approximately 10 minutes are needed to reach
the nominal heat output, which can be changed
using the parameter (P5).
N.B.:
the selection of the “Minimum heating
power” and “Maximum heating power” param-
eters, in the presence of a heating request, allows
switch-on of the boiler and power supply of the
modulator with current equal to the value of the
respective set value.
Minimum central heating output (P4)
Range of values which can
be set
Standard
setting
0 - 63 %
Set
according
to factory
inspection
Maximum heating output (P5)
Range of values which can
be set
Standard
setting
0 - 99 %
99
Central heating ignitions timer.
The boiler
has electronic timing, which prevents the
burner from igniting too often in central heat-
ing mode.
Central heating ignitions timer (P6)
Range of values which can
be set
Standard
setting
0 - 20 (0 - 10 minutes)
(01 equals 30 seconds)
6
(3’)
Central heating ramp timing.
In the ignition
phase, the boiler performs an ignition ramp in
order to arrive at the maximum power set.
Central heating ramp timer (P7)
Range of values which can
be set
Parameter
0 - 28 (0 - 14 minutes)
(01 equals 30 seconds)
28
(14’)
Содержание MINI NIKE 24 3 E
Страница 2: ......
Страница 21: ...19 PL ES TR SI CZ HU RO IE RU UA SK Fig 3 5 4 4 5 6 6 d d c ...
Страница 39: ...37 TR SI CZ HU RO IE RU UA SK ES PL Rys 3 5 4 4 5 6 6 d d c ...
Страница 56: ...54 PL SI CZ HU RO IE RU UA SK ES TR Şek 3 5 4 4 5 6 6 d d c ...
Страница 73: ...71 TR SI PL HU RO IE RU UA SK ES CZ Obr 3 5 4 4 5 6 6 d d c ...
Страница 90: ...88 TR PL CZ HU RO IE RU UA SK ES SI Sl 3 5 4 4 5 6 6 d d c ...
Страница 107: ...105 TR SI CZ PL RO IE RU UA SK ES HU 3 5 ábr 4 4 5 6 6 d d c ...
Страница 124: ...122 TR SI CZ HU RO IE PL UA SK ES RU Илл 3 5 4 4 5 6 6 d d c ...
Страница 141: ...139 TR SI CZ HU PL IE RU UA SK ES RO Fig 3 5 4 4 5 6 6 d d c ...
Страница 160: ...158 TR SI CZ HU RO PL RU UA SK ES IE Fig 3 5 4 4 5 6 6 d d c ...
Страница 177: ...175 TR SI CZ HU RO IE RU UA PL ES SK Obr 3 5 4 4 5 6 6 d d c ...
Страница 194: ...192 TR SI CZ HU RO IE RU PL SK ES UA Мал 3 5 4 4 5 6 6 d d c ...
Страница 197: ......
Страница 198: ...www immergas com This instruction booklet is made of ecological paper Cod 1 029101 Rev 15 030349 001 05 10 ...