3.19 CASING REMOVAL.
To facilitate boiler maintenance the casing can
be completely removed as follows:
- Remove the lower protection plate (10) by
loosening the two screws (11);
- disassemble the front (1) of the boiler by loos-
ening the screw (2) by 1/4 turn, push the front
upwards while pulling it towards you at the
same time to release it from the side (3) and
upper (4) hooks;
- undo the 2 screws (5) of the control panel (6);
- tilt the control panel (6) pulling it towards you
(see figure);
- remove the sides (7) loosening the screws (8),
push slightly upwards in order to release the
side from the seat (9) and pull towards yourself
(see figure);