26
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
Error
Code
Anomaly signalled
Cause
Boiler status / Solution
50
External probe miss-
ing or faulty
In the event the external probe is not connected or is faulty, the
anomaly is indicated.
Check the external probe connection (1)
(3).
58
Heat pump anomaly
In the event of a heat pump anomaly, room heating is ensured by
the boiler. All heat pump functions (room heating and cooling) are
inhibited.
Check the type of anomaly directly on the
remote panel display (see relative instruc-
tions manual).
In the event the heat pump does not fea-
ture any anomaly, check that the domestic
hot water inlet probe is working properly
(1) (3).
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Technical After-Sales Service).
(2) The boiler does not start, the heat pump stays active to satisfy the room heating and cooling requests
(3) The heat pump does not start, the boiler stays active to satisfy the room heating and domestic hot water production requests