Technical documentation
Technical documentation
STESP ed 02/02
24
EOLO SUPERIOR PLUS
INDICATORS
(display board)
DL1
This green LED lights up when the boiler is working in central-heating and antifreeze
mode.
DL2
This green LED lights up when the boiler is working in d.h.w. mode.
DL3
This orange LED lights up when the burner is operating.
Display
Depending on the condition, this indicates:
- the value of the temperature detected by the delivery sensor (NR) during operation
in central-heating, d.h.w., antifreeze and chimneysweep mode.
- The value set during the heating and domestic hot water circuit temperature
adjustment
(for 5 seconds).
- the letters CE with the CAR installed and the main switch in position
- The code number of the safety device that has tripped
01
= no ignition lock
02
= overheating safety device thermostat lock
03
= flue pressure switch contact not deviated (NO)
05
= NTC flow sensor faulty
10
= pump pressure switch safety
11
= flue pressure switch contact not at rest (NC)
12
= domestic hot water NTC sensor faulty
(storage tank NTC)
14
= connection between ignition control unit and board not correct /ignition control
unit faulty
31
= incompatible or faulty remote control
(optional)