Technical documentation
Technical documentation
STESP ed 02/02
6
EOLO SUPERIOR PLUS
- CIRCULATOR
This operates on the primary circuit return and is
located on the brass header assembly.
It is connected to the monobloc and exchanger by
means of threaded connecting pieces, while the
primary exchanger and expansion vessel are
connected by coupling pipes (2) with O.R. seal (3),
fastened with special forks (1).
.
- HEAD - FLOW GRAPH
The curve that represents the relation between the flow rate and the available head depends on
system bypass adjustment which, depending on its position, gives the system greater or less head.
The graph below refers to the pump operating at top speed with:
- A
= Bypass disconnected
(screw fully tightened)
- B
= Standard bypass adjustment
(screw tightened by 4.5 turns with respect to fully-tightened
position)
- C
= Bypass open
(screw fully loose)
- PRIMARY EXCHANGER
This is a water-gas blade type exchanger with
copper pipes and fins at the outlet of which an
NTC heating probe (5) is located.
The four pipes passing through the exchanger are
connected in parallel (1) two by two, to reduce
flow resistance to the utmost and provide a greater
available head.
It is connected to the pump flow and to the
primary circuit flow by means of coupling pipes
(2) with O.R. seal (4).
These are secured by means of special forks (3).