Technical documentation
Technical documentation
STESP ed 02/02
26
EOLO SUPERIOR PLUS
EOLO 24 SUPERIOR PLUS TECHNICAL DATA
Nominal heat input
kW (Kcal/h)
30.0 (25834)
Minimum heat input
kW (Kcal/h)
12.2 (10466)
Nominal heat output (useful)
kW (Kcal/h)
27.9 (24000)
Minimum heat output (useful)
kW (Kcal/h)
10.5 (9000)
Useful heat efficiency at rated power
%
92.9
Useful heat efficiency at 30% load at nominal output
%
89.5
Loss of heat at shell burner on / off
%
0.3 / 0.08
Loss of heat at flue burner on / off
%
6.8 / 0.05
Gas nozzle diameter
(G20)
mm
1.30
Gas pressure
(G20)
mbar (mm H
2
O)
20 (204)
Gas nozzle diameter
(G30)
mm
0.75
Gas pressure
(G30)
mbar (mm H
2
O)
29 (296)
Gas nozzle diameter
(G31)
mm
0.75
Gas pressure
(G31)
mbar (mm H
2
O)
37 (377)
Max operating pressure of heating circuit
bar
3
Max operating temperature of heating circuit
ºC
90
Adjustable heating temperature
ºC
38 - 85
Total volume of expansion vessel
l
8
Expansion vessel preloading
bar
0.8
Amount of water in boiler
l
4.0
Available head capacity 1000 l/h
kPa (m H
2
O)
39 (4.0)
Working heat output for the production of hot water
kW (Kcal/h)
27.9 (24000)
D.h.w. adjustable temperature.
ºC
20 - 60
80 l and 105 l storage tank unit d.h.w. flow limiting device
l/min
12
D.h.w. circuit dynamic minimum pressure
bar
0.1
Max operating pressure of d.h.w. circuit
bar
8
120 l storage tank specific flow capacity (
∆
T 30ºC)
l/min
26.6
105 l storage tank specific flow capacity (
∆
T 30ºC)
l/min
23.8
80 l storage tank specific flow capacity (
∆
T 30ºC)
l/min
20.9
Specific flow capacity in continuous service (
∆
T 30ºC)
l/min
13.3
Full boiler weight
kg
49.5
Empty boiler weight
kg
45.5
Power connection
V / Hz
230 / 50
Rated input
A
0.71
Installed power
W
150
Power absorbed by circulator
W
88
Power absorbed by fan
W
26
Appliance electrical system cutout
-----
IP44